layout. The efficacy of the surge protection implemented in each product containing
the PLT-22 transceiver must always be verified empirically, since factors such as
PCB layout and packaging can influence the results as much as the choice of
protection components.
The level of surge protection required for a given product often depends on the
installed location of the product to be protected. Devices connected to branch circuits
within a building or home are typically subject to the lowest level of surge stress.
Devices connected at, or close to, the power entry point of a building or home, e.g.,
electrical meters and main breaker panels, are subject to higher levels of surge
stress. Devices connected to outdoor wiring are subjected to the highest surge stress
of all.
Standard tests for surge immunity are defined in IEEE C62.41-1991
17
and CEI/IEC
1000-4-5
16
. Both documents classify levels of surge stress by the type of surge wave-
form (either Ring wave or Combo wave), surge voltage, and surge current. In
addition to describing standard test methods, both documents also suggest surge
immunity levels for the device environments described above.
Comparison of the two documents reveals that their recommended test procedures
are identical, while the suggested immunity levels called out in IEEE C62.41-1991
substantially exceed the suggested immunity levels of CEI/IEC 1000-4-5. The more
severe (and thus more conservative) immunity levels called out in IEEE C62.41-1991
were used in characterizing the recommended surge protection circuitry shown in the
PLT-22 transceiver coupling circuit examples that follow.
The line-to-neutral coupling circuits documented later in this chapter have been
demonstrated to meet the IEEE C62.41-1991 "high system exposure" levels with no
damage for
branch circuit applications
,
power entry applications
, and
outdoor wiring
applications
, up to the limits of the available test equipment.
Table 4.1 summarizes the surge immunity of the PLT-22 transceiver in conjunction
with the specified line-to-neutral coupling circuits.
4-14
Coupling
Circuits
Содержание LONWORKS PLT-22
Страница 6: ...iv Echelon...
Страница 14: ...1 8 Introduction...
Страница 67: ...LONWORKS PLT 22 Transceiver s User Guide 5 7 Figure 5 3 Capacitor Input Power Supply Schematic...
Страница 92: ...6 10 Design and Test for Electromagnetic Compatibility...
Страница 110: ...7 18 Communication Performance Verification...
Страница 114: ...8 4 References...
Страница 118: ...A 4 Appendix A...