This chapter discusses the installation of a mezzanine card and XMCspan module.
The following procedures are detailed:
•
on page 22
•
Installing the Primary XMCspan
on page 24
•
Installing a Secondary XMCspan
on page 26
•
on page 28
•
Note:
Before proceeding with the instructions in this chapter, make sure that you check the installation instructions
in the VME base board Installation and Use manual.
ENVIRONMENTAL CONSIDERATIONS
The following environmental conditions must be tested and proven in the used system configuration. These
conditions refer to the surroundings of the board within the user environment.
Note:
• Operating temperatures refer to the temperature of the air circulating around the module and not to the
component temperature.
• Forced air cooling within the system is required to make sure that the operating conditions are met.
• The environmental values listed in the table only apply to the board without any accessories. If you install
accessories, you must consider their environmental requirements.
High humidity and condensation on the surface of the board causes short circuits. Do not operate the board outside the
specified environmental limits. Make sure the board is completely dry and there is no moisture on any surface before ap-
plying power.
Non-Operating
Operating
Requirement
-40°C (-40°F) to +85°C (+185°F)
0°C (32°F) to +55°C (+131°F)
This may be limited by the type of hard disk
used.
Temperature
+/- 1°C/min
+/-0.5°C/min
Temperature Change
6806800H03A | XMCspan Installation and Use |
19
Hardware Preparation and Installation
Содержание XMCSPAN-001
Страница 1: ...XMCspan Installation and Use...
Страница 5: ...Manufacturers Documents 43 Related Specifications 44 6806800H03A XMCspan Installation and Use v...
Страница 6: ...6 XMCspan Installation and Use 6806800H03A Declaration of Conformity...
Страница 31: ...Figure 1 XMCspan with SCANBE Handles 6806800H03A XMCspan Installation and Use 31 Controls LEDs and Connectors...