REMOVING THE XMCSPAN
This procedure is applicable to the primary and secondary XMCspan.
Dangerous voltages, capable of causing death, are present in this equipment. Use extreme caution
when handling, testing, and adjusting.
Inserting or removing modules with power applied may result in damage to module components. Avoid touching areas
of integrated circuitry as static discharge can damage these circuits.
1.
Attach an ESD strap to your wrist.
2.
Attach the other end of the ESD strap to an electrical ground.
The ESD strap must be secured to your wrist and to ground throughout this procedure.
Note:
The system chassis may not be grounded if it is unplugged.
3.
Perform an operating system shutdown.
4.
Turn off the AC or DC power and remove the AC cord or DC power lines from the system.
5.
Remove chassis or system cover(s) as necessary for access to the VME base board.
6.
If the VME base board has already been installed in a VMEbus card slot, carefully remove it.
7.
Remove the four screws (Phillips type) from each corner of the XMCspan.
8.
Gently remove the XMCspan, and then remove the standoffs from the VME base board.
28
| XMCspan Installation and Use | 6806800H03A