1 DC1 device series
1.6 Voltage categories
26
DC1…20… and DC1…OE1 Variable Frequency Drives
02/20 MN040059EN
www.eaton.com
•
DC1-
1D
…
•
Single-phase mains connection, rated operating voltage of 115 V with
internal voltage doubler
•
U
LN
= 1~, 110 - 115 V ±10 %, 50/60 Hz
•
Ie = 2.3 - 5.8 A
•
Motor: 0.37 - 1.1 kW (230 V, 50 Hz), 1/2 - 1-1/2 HP (230 V, 60 Hz)
Figure 8: DC1-1D…
•
DC1-
12
…
•
Single-phase mains connection, rated operating voltage 230 V
•
U
LN
= 1~, 200 - 240 V ±10 %, 50/60 Hz
•
I
e
= 2.3 - 15.3 A
Motor: 0.37 - 4 kW (230 V, 50 Hz), 1/2 - 5 HP (230 V, 60 Hz)
Figure 9: DC1-12…
Motor
L1
N
PE
U
V
W
L1/L
L2/N
M
3 ∼
I
e
BR
DC+
FS1, FS2
Brake Chopper
(FS2)
230 V (U
LN
= 1 ~ 230 V)
Motor
L1
N
PE
U
V
W
L1/L
L2/N
M
3 ∼
I
e
BR
DC+
FS1, FS2, FS3
Brake Chopper
(FS2, FS3)
230 V (U
LN
= 1 ~ 230 V)
EMC Filter