Page 60
Chapter 9: System Options Menu
This menu contains options that affect the working of the alarm system as a whole.
Note:
The default settings for these options are compliant with EN50131, see page 17.
Changes to some of the defaults may render the system non-compliant.
Wired Zone Type
This option lets you change the zone wiring type for the control unit.
The control unit prompts you to select the zone wiring type when you power up a control
unit for the first time, or when you restore the control unit to factory defaults (see page 69).
Please refer to page 9 for details of the wiring types.
User Access
Use this option to give users access to various system facilities
HUA Keys Active
This option allows users to start an HUA alarm from the control unit and one-way radio
keypads by pressing both Hold Up Alarm keys at the same time. This option is not affected
by allocating keypads to specific partitions.
Select Yes to make the HUA keys functional. Select No to disable the keys.
Note:
If HUA Confirmation has been enabled in
System Options
– Confirmation –
BS8243
, two separate HUA events are needed within the confirmation time to
generate a confirmed HUA alarm. See page 65 for HUA Confirmation Time.
To enable HUAs from a FOB-2W-4B, you must set
System Options
– Confirmation
Mode
to
Basic
(see page 62). EU control units, always use Basic confirmation
mode. A Master User must then set
User Menu
– System Config – Remotes – HUA
Function
to
Enabled
(the option does not appear if Confirmation Mode is BS8243 or
DD243).
Quick Set
Note:
If you enable quick set, the control unit no longer complies with EN50131.
This option controls the operation of the A, B, C or D keys at one-way keypads, and the
Home key at the control unit (if configured to set the system; see page 34).
Yes
– Allows users to set the alarm system by pressing A, B, C or D or the Home key
without entering an access code.
No
– Users must enter an access code (or present a tag) before pressing A, B, C or D or
Home key.