If the first ("unconfirmed") alarm is caused by the expiry of the entry timer, then
for:
DD243
– A further two zones that are not on the entry route must be triggered
to activate the output.
BS8243
– One zone not on the entry route must be triggered to activate the
output.
Note:
A confirmed alarm activates any output programmed of type Confirmed Alarm (page
A confirmed alarm is communicated only when the
Alarm Response
is set to
Siren+Comms (see page 51).
A confirmed hold-up alarm (generated by two hold-up alarms or a hold-up alarm
and tamper alarm) only when
Confirmation Mode
is BS8243.
The Master User can enable or disable hold-up functions for all FOB-2W-4Bs by
using
User Menu
– System Config – Remotes – HUA Function
. This requires Basic
confirmation mode and is not compliant with DD243 or BS8243.
Confirmation Time
This is available for only for UK control units and when
Confirmation Mode
is set to DD243
or BS8243.
The option determines the length of the confirmation time for intruder alarms. You can
select any time between 1 and 60 minutes. Confirmation times less than 30 minutes do not
comply with BS8243 or DD243.
After Entry
This is available for only for UK control units and when
Confirmation Mode
is set to DD243
or BS8243.
Never
The control unit turns alarm confirmation off if the user enters by the entry door (used
for DD243:2004 clauses 6.4.2 and 6.4.4 and BS8243:2010).
1 zone
The control unit starts a confirmed alarm if the intruder activates one or more zones
(not on the entry route) after entering the premises through the final exit zone.
2 zones
The control unit starts a confirmed alarm if an intruder activates two or more zones
(not on the entry route) after entering the premises through the final exit zone (used
for DD243:2004 clauses 6.4.5)
Note:
This option is not available if you have selected
BS8243 for Confirmation Mode.
Entry Keypad Lock
This is available for only for UK control units and when
Confirmation Mode
is set to DD243
or BS8243.
The option determines whether the user can unset the system by entering an access code
after opening the entry door. Select one of the following: