Test Menu
Page 104
b) Press both keys of the two-button HUA.
The display shows “Hold Up Alarm Key”.
c) Press the Unset key. The display shows “System Unset Key”.
d) Test all the numeric keys four at a time (six at a time if using six-digit codes)
remembering to press A after each group of four (or six). For example, if you press
“4567A”, the display should show “4567A”.
Note:
You cannot test the “*” and “#” keys on an i-rk01 radio keypad.
Walk Test
The walk test menu provides several different ways of organising a walk test.
When you select a
Walk Test
option (apart from
Chime
), the display shows the first item in
a list of the detectors available for test. Walk around the area you wish to test and trigger
each detector. If
Chime
is set to “Yes”, every time you trigger a detector, internal sounders
give confirmation tone. The bottom-right corner
of the display shows an “A” if you trigger
the Alarm input and a “T” if you trigger the Tamper.
Note that if a zone has the Masking attribute enabled and the device is masked during the
walk test, the
display will also show a “T”.
The top of the display shows the number of zones left to test. The control unit decreases
the number of zones every time you trigger an individual Alarm input.
The display shows the zone name. To see the zone number press
or
.
Press
to end the test.
If you wish to see which zones have not yet been tested, press . As you test each zone, it
will disappear from the display. Press again to return to the full list of zones.
Chime
Use this option to select Once, On or Off. Once causes internal sounders to chime
only once for each zone that is triggered during the walk test. On generates a chime
every time a zone is triggered. Off switches off chiming.
System
This option allows you to walk round the entire system and test all the zones.
Partitions
Use this option to select one or more partitions, and test the zones only within those
partitions.
Use
or
to scroll up and down the list of partitions. Press
or
to display
“Yes” at the end of the bottom line to mark the partition as one you want to test.
Zones
This option lets you select one or more individual zones, and test only those zones
and no others.
Use
or
to scroll up and down the list of zones. Press
or
to display “Yes” at
the end of the bottom line to mark the zone as one you want to test.
Zone Resistances
When you select Zone Resistance, the display shows the first of the available wired
detectors. Press
or
to see the other detectors in the list.
The display shows the zone name. To see the zone number press
or
.