Settings Options and Partitions Menus
Page 50
a PIR may still be in lockout, during which it cannot send a signal to complete the
setting process.
Instant Set
The system sets immediately and without any setting tone. The control unit and
internal radio sounders give confirmation tone when the system is set.
Note:
This option does not comply with BS8243:2010.
Silent Set
The system sets after the time programmed in the Entry/Exit Time menu but does not
give any exit tones.
On entry, the control unit and internal radio sounders give entry tones.
Note:
This option does not comply with BS8243:2010.
Lock Set
Use this setting if you are using a lock to set the system.
To use
Lock Set
, you must:
Configure a Lock Set zone (see page 30) that is activated by a suitable lock
(located on the final exit door).
Configure a Final Exit zone (see page 27) connected to the final exit door.
Note:
It is recommended that you do not use
Lock Set
within a part set, since the
results may not be predictable.
Setting:
Once the user has started the setting sequence, the exit tone sounds, which
continues until the user closes the Final Exit door and operates the lock. When the
Settle Time
(page 51) expires, the control unit sets the system and converts the Final
Exit zone in the set partition to a zone of type Normal Alarm.
Unsetting:
When a user de-activates the Lock Set zone, the control unit converts
any zone originally programmed as Final Exit back to Final Exit (so that the entry time
starts when the user opens the entry door) and starts a warning tone (distinct from
the entry tone). If the user activates the Lock Set zone again without starting the
Entry Timer, the control unit changes all Final Exit zones back into Normal Alarm
zones and stops the warning tone.
Note:
If you use
Lock Set
, you must set
After Entry
(page 63) to Never in order to
disable confirmation and comply with BS8243.
Exit Terminate
Setting:
The user must start the setting sequence in the normal way, and then
complete setting by activating an Exit Terminate zone (see page 29) once they have
left the protected area.
When the user starts the setting sequence, the control unit gives the exit tone for the
selected partition(s) and the exit time does not expire. Once the user completes the
setting sequence, the system sets when the Settle Time (page 51) expires.
Unsetting
: The user can unset the partition using any of the following methods:
a) By using the Unset button on a remote control.
b) By activating a Final Exit zone allocated to the partition (to start an entry timer) and
then entering an access code or presenting a proximity tag.
Note:
This method does
not comply with BS8243 clause 6.4.
As Partition 1
This option appears for all partitions except partition 1. If you select this option, the
partition will use the same exit mode as partition 1.