Settings Options and Partitions Menus
Page 58
At the end of the period, the control unit stops the warning tone, sets the affected
partition(s) without any delay and deactivates any outputs of type Autoset Warning.
Warning Tone
Press
or
to choose between Audible or Silent. When Silent, the control unit will
NOT sound a warning tone for the event (although the warning timer will still
operate).
If a warning tone is due from more than one event at the same time, and any of the
tones is set to "Audible", the tone will be audible.
Edit Event
This option allows you to edit individual parts of an event.
Delete Event
Use this option to delete an event.
Add Exception
Use this option to create an exception. During the time specified by the exception, none of
the events that have the exception will take place. When you add an exception, the control
unit guides you through the following steps:
Name
Enter up to 12 characters or press
to leave the default name.
Exception Start Time
Specify the time you want the exception to start, then
to display the next prompt.
T
he time “00:00” is midnight, at the beginning of a new day.
Exception Start Date
Specify the date you want the exception to start (for example, 31/12 for 31
st
December).
Exception End Time
Specify the time you want the exception to end.
Exception End Date
Specify the date you want the exception to end.
Edit Exception
This option allows you to edit individual parts of an exception.
Delete Exception
Use this option to delete an exception.
Deferring Calendar Setting
During the calendar set warning time, a user can interrupt the setting process. To do this,
they must enter their access code (or present a prox tag). The user can then do one of the
following:
Press
or
to see details of which partitions or part of the system is about to set.
Press
to allow the setting event to proceed.
Press
to defer setting for 30 minutes. Note that for a partitioned system, the user
must belong to the partition that is due to be set.