Settings Options and Partitions Menus
Page 52
Note:
All HUAs are disabled when an installer is using the Installer menu.
In a partitioned system,
HUA Response
applies to both a full-set or part-set
partition.
For a part-setting system, this option appears in
System Options
.
PZ Unset Response
Specifies the system response for activations of zones of type Perimeter in the unset state.
In a partitioned system, each partition can have different response. In a part-setting
system, this option applies to the complete system.
Note:
For a part-setting system, this option appears in
System Options
.
Silent
Activation inserted into non-mandatory log.
No internal sounders.
Outputs of type Perimeter and Perimeter Timer activate.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Internal
Activation inserted into non-mandatory log.
Internal sounders activate.
Outputs of type Perimeter and Perimeter Timer activate.
Internal sounders silenced by user code, etc.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Siren
Activation inserted into non-mandatory log.
Internal and external sounders activate.
Outputs of type Perimeter and Perimeter Timer activate.
Internal and external sounders silenced by user code, etc.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Full
Activation inserted into non-mandatory log.
Internal and external sounders activate.
Outputs of type Perimeter and Perimeter Timer activate.
Communications active.
Internal and external sounders silenced by user code, etc.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Communications restored by user code entry.