System Options Menu
Page 69
Radio Devices
Deletes the IDs for learned radio devices. Scroll through the list of devices and select
Yes for each type you want to delete, then press
to action your selection. The
Keypads
option deletes one-way radio keypads.
Outputs
Defaults all output configuration.
Setting Information
Defaults all setting options.
System Options
Defaults all options in the
System Options
menu.
Communications
Defaults all configuration for communications.
Factory Defaults
This removes all configuration from a control unit, including all names and stored texts, but
not the log.
Note:
You may wish to make a backup of the configuration before using
Factory Defaults
.
You can do this using the Downloader software or the web interface.
To use the option:
1.
Select
Factory Defaults
and confirm the operation when prompted.
2.
Answer the configuration prompts. These are similar to those displayed when you
first powered-up the control unit (see page 12).
3.
To delete all users, remove and reconnect all power to the control unit immediately
after using
Factory Defaults
(before you exit the Installer menu). You will need to
repeat step 2 when you re-apply power.
4.
Exit the Installer menu.
Note:
You will see PSTN Line Fault if the control unit uses PSTN communications. You
will need to re-enter the appropriate telephone numbers (or disable communications
using
Communications
– ARC Reporting – Call Mode
).
If you are using the web interface, re-enable the web browser interface and re-enter
the control unit’s own IP address (page 94). Note that you will also have to use
User
Menu
– System Config – Facilities On/Off – Remote Access
to enable remote
access.
Installer Name
When logging in to the web interface, you must enter the username specified by this
option. The username is case sensitive.
Installer Code
This code allows you to enter the Installer menu (which also carried out an Installer reset).
When logging into the web interface, you must key into the password field the same code
as you have programmed into the
Installer Code
field.
The Installer code does not allow you to set or unset the system.