24
XCHARGEIN MOBILITY INSTALLATION MANUAL
MN191005EN April 2021 www.eaton.com
00 Title
Figure 19. How to pair two control units to deliver max. 16 A
Number Description
1
External controller (breaker)
2
Active
3
Inactive
6.5.2 Load balance between two “back to back” charging stations
Two xChargeIn Mobility 22 kW AC EV chargers can be paired in order to balance the load. In this way, the maximum
electrical current for both charging stations is limited to 32 A.
If two charging stations are used, the second charging station is limited to 16 A.
The “back to back” connection is made on CU terminals 10 and 12, as shown in the following figure.
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
18
17
16
15
14
13
12
11
10
18
17
16
15
14
13
12
11
10
6.5.3 Switch the charging station off
The charging station is deactivated on CU terminal 3 by turning off the 24 V input, as shown in the following figure.
In this way the unit will deliver no power.
Figure 20. How to deactivate the unit on CU terminal 3
1
2
3
+24V
9
8
7
6
5
4
3
2
1
18
17
16
15
14
13
12
10
11