19
Installation Guide
GREEN MOTION BUILDING PRO
www.eaton.com
FCC
FCC ID
This device complies with part 15 of the FCC rules . Operation is subject to the following two conditions:
1 . This device may not cause harmful interference, and
2 . This device must accept any interference received, including interference that may cause undesired operation .
The J1772 cord-set is the only replaceable parts in your Building Pro charger . Your Green Motion EV charger contains no other
user serviceable parts . Do not attempt to repair or service any other part of the unit yourself . If the unit requires servicing,
please contact Eaton customer service . The installation, maintenance, and servicing of your EV charger must only be
performed by qualified personnel in accordance with applicable local regulations . Protect your EV charger from any external
impact . Take appropriate precautions with electronic medical implants . Disconnect the main service power to your charger
before cleaning the unit . Do not use cleaning solvents to clean any part of your charger . Use a clean, dry cloth to remove
accumulated dust and dirt . Ensure that the EV charging cable is positioned in such a way so that it will not be stepped on,
tripped over, or subjected to damage or stress . Do not close your garage door on the charging cord . Best practice for EV
charging cable storage when not in use is to wrap the cord around the premium cord hook and holster provided . There
should be visual inspection at the time of use of the cable for cracks, nicks or cuts to ensure the integrity of the cable . There
should be visual inspection of the connector for damage and contamination prior to use .
Model Number
Wi-Fi Module FCC ID
Wi-Fi Module IC
Cellular Module FCC ID
Cellular Module IC
GMEV48CME1-WC
2AD56HLK-RM08S
30529-HLKRM08S
N/A
N/A
GMEV48CMC1-WC
2AD56HLK-RM08S
30529-HLKRM08S
RI7LE910CXNF
5131A-LE910CXNF
Wi-Fi/Ethernet/4G Connectivity
Connectivity and various other settings are available through the LCD’s ‘Administration
Menu’ . Default password to access these settings is ‘eaton’ . Users will be required to
update to a stronger password . Refer to the product web page QR code to the right for
detailed instructions on commissioning the charger using Wi-Fi, Ethernet or cellular and
connect to a CPO provider .
Note: Please validate cellular reception at the installation site if using a SIM card for EV
charger commissioning .
Maintenance
Scan for detailed instructions
on commissioning the charger
using Wi-Fi, Ethernet or cellular
and connect to a CPO provider.
Canada low-power license exempt radio communication devices (RSS-210)
Common information operation is subject to the following two conditions:
1 . This device may not cause interference, and
2 . This device must accept any interference, including interference that may cause undesired operation of the device .
RF radiation exposure statement
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment . This equipment
should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body .