Installation Guide

GREEN MOTION BUILDING PRO

   www.eaton.com

Installation

Important safety instructions

 DANGER

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN 

DEATH, PERSONAL INJURY, OR PROPERTY DAMAGE. CIRCUIT 

BREAKERS MUST BE INSTALLED AND SERVICED BY A QUALIFIED 

ELECTRICIAN. REMOVE ALL POWER SOURCES TO THE PANEL 

BEFORE STARTING INSTALLATION OR MAINTENANCE. 

 WARNING

THIS EQUIPMENT SHOULD BE INSTALLED, ADJUSTED, AND 

SERVICED BY QUALIFIED ELECTRICAL PERSONNEL FAMILIAR 

WITH THE CONSTRUCTION AND OPERATION OF THIS TYPE OF 

EQUIPMENT AND THE HAZARDS INVOLVED. FAILURE TO OBSERVE 

THIS PRECAUTION COULD RESULT IN DEATH OR SEVERE INJURY.  

 

READ THIS MANUAL THOROUGHLY AND MAKE SURE YOU 

UNDERSTAND THE PROCEDURES BEFORE YOU ATTEMPT TO 

OPERATE THIS EQUIPMENT. THE PURPOSE OF THIS MANUAL IS 

TO PROVIDE YOU WITH INFORMATION NECESSARY TO SAFELY 

OPERATE, MAINTAIN, AND TROUBLESHOOT THIS EQUIPMENT. 

KEEP THIS MANUAL FOR FUTURE REFERENCE. 

 

DO NOT USE THIS PRODUCT IF THE EV CONNECTOR CORD IS 

FRAYED, HAS DAMAGED INSULATION, OR HAS ANY OTHER 

INDICATION OF DAMAGE. 

 

DO NOT USE THIS PRODUCT IF THE EV CHARGER, THE EV 

CONNECTOR, OR THE LOADCENTER IS BROKEN, CRACKED, OPEN, 

OR SHOWS ANY OTHER INDICATION OF DAMAGE. 

 

INTENDED FOR USE WITH PLUG-IN ELECTRIC VEHICLES ONLY. 

PREMISE VENTILATION NOT REQUIRED. 

 

THIS DEVICE SHOULD BE SUPERVISED WHEN USED AROUND 

CHILDREN.

 WARNING

TURN OFF OR DISCONNECT THE POWER SUPPLYING THIS 

EQUIPMENT BEFORE BEGINNING WORK. THIS MAY REQUIRE THAT 

YOU CONTACT YOUR ELECTRIC UTILITY TO DISCONNECT POWER TO 

AN EXISTING LOADCENTER. THE LINE SIDE OF THE MAIN BREAKER 

IS ENERGIZED UNLESS POWER IS DISCONNECTED UPSTREAM. 

EATON WILL NOT ASSUME RESPONSIBILITY FOR PROPERTY 

DAMAGE OR PERSONAL INJURY RESULTING FROM MISUSE OF THE 

INFORMATION IN THIS PUBLICATION.

NOTICE

INSTALL EQUIPMENT IN CONFORMANCE WITH CODES.

Grounding instructions

 WARNING

IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING 

CONDUCTOR IS ABLE TO RESULT IN A RISK OF ELECTRIC SHOCK. 

CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICEMAN IF YOU 

ARE IN DOUBT AS TO WHETHER THE PRODUCT IS PROPERLY 

GROUNDED.

For a permanently connected product 

This product must be connected to a grounded, metal, 

permanent wiring system, or an equipment-grounding 

conductor must be run with the circuit conductors and 

connected to the equipment grounding terminal or lead  

on the product .

This product must be installed in accordance with the 

National Electrical Code

®

 (NEC

®

) and any applicable local 

codes . Before installing equipment, check with your local 

electrical inspector for requirements and information . If 

you have questions or need assistance, contact a qualified 

electrical contractor . 

SAVE THESE  INSTRUCTIONS

 .

Содержание Green Motion Building Pro

Страница 1: ...Installation guide Green Motion Building Pro Green Motion chargers Scan here for Spanish translations Scannez ici pour les traductions en espagnol...

Страница 2: ...LLATION Safety information 3 General reference 4 A Preparing the EV charger s 5 B Mount an EV charger to a wall 8 C Mount an EV charger to a pedestal 11 D Mount a second EV charger to a pedestal 16 FC...

Страница 3: ...bolt 18 8 Stainless Steel Hex Head Screw 1 4 20Thread Size 3 4 Long P 1 4 20 serrated flange nut High Strength Steel Serrated Flange Locknut Grade 8 Zinc Plated 1 4 20Thread Size R 1 4 Stainless Stee...

Страница 4: ...link Blue Long Red Charging EVSE EV Fault 1 No Blink Green Short Blue Vehicle connected Idle Ready 1 Refer to the troubleshooting section for help on various faults Idle green Charging blue Fault red...

Страница 5: ...CTRIC VEHICLES ONLY PREMISE VENTILATION NOT REQUIRED THIS DEVICE SHOULD BE SUPERVISED WHEN USED AROUND CHILDREN WARNING TURN OFF OR DISCONNECT THE POWER SUPPLYING THIS EQUIPMENT BEFORE BEGINNING WORK...

Страница 6: ...ore than 4 ft 1 2 m above the floor level for indoor loca tions and 24 inches 600 mm above the grade level for outdoor locations WARNING Risk of Explosion This equipment has arcing or sparking parts t...

Страница 7: ...is setting Default password to access Admin settings is eaton Users will be required to update to a stronger password Table below provides Circuit Breaker rating required for each output current optio...

Страница 8: ...INSTALLATION PEDESTAL INCLUDED punch out the larger knockout hole as pictured Only punch out the smaller knockout if you plan to install ethernet Do not reinstall lower front panel For ethernet For re...

Страница 9: ...card and insert a new SIM Place the SIM card module back into its slot on the printed circuit board Pay attention to the orientation of the SIM card module to avoid damage The black wire connecting t...

Страница 10: ...Align mounting plate C on wall and secure with four M6 screws F If no stud is available use an anchor E provided Align premium holster D and secure with two M6 screws F If no stud is available use an...

Страница 11: ...L1 L2 YAD4CM6E14 Recommended lug GND YAD8CM5E10 Torque lbf in 40 WireType Copper ScrewType L1 L2 M6 GND M5 Caution Follow all local electric codes when wiring this EV Charger Local electric code shal...

Страница 12: ...EV CHARGER RE CHECK ALL ELECTRICAL CONNECTIONS AFTER ALL WIRING HAS BEEN COMPLETED Reconnect power to the upstream circuit by switching circuit breaker to the ON position Energize the loadcenter or t...

Страница 13: ...estals remove the top and bottom panels On the front of the pedestal remove the four 1 4 20 Hex head bolts neoprene washers and 1 4 20 serrated flange nuts Remove NEMA plug Only remove second NEMA plu...

Страница 14: ...tall the premium cord holster D onto the pedestal with the two 1 4 20 Hex head bolts N neoprene washers R and 1 4 20 serrated flange nuts P STEP C 4 Reference 1 4 20 Hex head bolt N x6 Neoprene washer...

Страница 15: ...and two 1 o rings J to secure it on the interior of the charger A and on the interior of the EV pedestal IF INSTALLING ETHERNET secure the 1 2 threaded plastic pipe nipple K using a 1 2 plastic nut L...

Страница 16: ...efully plug into the RJ45 connector L1 L2 Ground Ethernet RJ45 connector 48 A 40 A 32 A Recommended Wire Gauge L1 L2 4 AWG 6 AWG 8 AWG Recommended Wire Gauge GND 10 AWG 10 AWG 10 AWG Recommended lug L...

Страница 17: ...circuit breaker to the ON position Energize the loadcenter or the panelboard The EV charger A electronics should power immediately and the LCD will indicate the status of the charger Replace the lowe...

Страница 18: ...rence Mounting plate C 1 2 o ring M 1 4 20 Hex head bolt N x3 Neoprene washer R x3 1 4 20 serrated flange nuts P x3 Install the mounting plate C to the top panel using the top three holes with 1 4 20...

Страница 19: ...0 serrated flange nut to secure the lower mounting hole IF INSTALLING ETHERNET be sure the 1 2 o ring M is correctly seated around the smaller hole Then feed the 1 2 threaded plastic pipe nipple K thr...

Страница 20: ...ing 10 silver speed screws Reference Premium cord holster D 1 4 20 Hex head bolt N x2 Neoprene washer R x2 1 4 20 serrated flange nuts P x2 STEP D 4 STEP D 5 Replace both lower front panels of the EV...

Страница 21: ...visual inspection at the time of use of the cable for cracks nicks or cuts to ensure the integrity of the cable There should be visual inspection of the connector for damage and contamination prior t...

Страница 22: ...ee 3 year from the date of original purchase In the event any Product fails to comply with the foregoing warranty Seller will at its option either a repair or replace the defective Product or defectiv...

Страница 23: ...f the EV charger is wired properly and the circuit breaker is closed Restore the EV connector back to the charger and try to reset the circuit breaker powering the charger If the problem still persist...

Страница 24: ...oulevard Cleveland OH 44122 United States Eaton com 2023 Eaton All Rights Reserved Printed in USA Publication No IL191021EN Rev 01 Eaton is a registered trademark All trademarks are property of their...