ET5050 Crimp machine operator´s manual E-EQCR-TT003-E2 May 2019
Filling hydraulic fluid reservoir
1. Machine is shipped without hydraulic fluid.
2. Remove the oil cap on the top rear of machine.
3. Fill the reservoir with new, clean AW46 (ISO46)
hydraulic fluid. (see page 5).
4. Filter oil through a 10 micron filter to remove any
contaminates before filling machine.
5. Replace the vented oil filler cap when the correct oil level has
been verified with the oil sight glass. (See figure 3).
6. Review instructions below for preparing the hydraulic system
prior to operating.
Note: Over filling hydraulic reservoir may result in blown seals and
machine leakage.
!
Figure 2
Figure 3
Machine setup and installation
Read and understand the operator’s manual before
attempting to operate this machine. Failure to follow
operating instructions could result in injury or damage
to the equipment.
Environment
1. The machine should be installed indoors on a level
surface and operated in a clean dry environment, under
normal atmospheric pressure. Avoid high humidity, dusty
environments. (Optimal operating temperature: 50°F to 95°F)
2. Cover machine when not in use.
Never get underneath the machine and keep the load low
during transport.