9
EATON
ET5050 Crimp machine operator´s manual E-EQCR-TT003-E2 May 2019
Tooling installation - using
Quick Die Change (QDC) tool
After fitting and hose selections are made on menu screens,
screen will display correct tooling for application.
Position the QDC tool with crimp dies in the center of the
crimp head. Make sure the holding pins are aligned with
the bore holes in the base or intermediate dies and
gradually jog - close the crimp head while confirming all
eight pins are aligned.
Remove the QDC tool and retract the crimp head. Confirm
the crimp dies are loaded correctly and secured to the base
dies. No space should be visible between the dies and base
dies. Then press the check button to acknowledge installation
of correct tooling for application.
Figure 5
Figure 7
Figure 8
Step 1
Step 3
Step 4
Align and insert the eight pins of the QDC tool
(ET5040C-0004) with the holes in the front of desired crimp
dies in the optional storage rack (ET5040C-0014). Rotate the
handle to the right (clockwise) to remove the crimp dies from
the storage rack.
Figure 6
Step 2