Blocking the Case Flushing Feature
Procedure to Disable the Shuttle Valve Assembly (continued)
Important
This procedure applies
to HMR Motors with
“Standard” or “Optimized”
Shuttle Valve Assemblies.
For unit with “Dampened”
Shuttle Valve Assembly
please move to “Procedure
to Disable the Purge Valve”
section near the end of this
document.
Reinstall the Washer onto the Disabled Shuttle Spool.
6
Reinstall the Washer/Disabled Shuttle Spool
subassembly back into the Shuttle Body.
7
Reinstall the spring.
8
Reinstall the M22 Plug. Torque the M22 Plug to
122 N-m (90 ft-lb).
9