9
EATON
Duraforce HMR Conversion Procedures Manual E-MOPI-TM005-E July 2012
Closed Loop
Purge Valve
Open Loop
Purge Valve
Exchanging Purge Valves
Set Up and Procedure
Procedure to Exchange a Closed Loop Purge Valve
with an Open Loop Purge Valve
Remove the Closed Loop Purge Valve
with the 13mm wrench.
Install the Open Loop Purge Valve and tighten it with
the 17mm wrench. Torque it to 15 N-m (11 ft-lb).
Procedure to Exchange an Open Loop Purge Valve
with a Closed Loop Purge Valve
Remove the Open Loop Purge Valve
with the 17mm wrench.
Install the Closed Loop Purge Valve and tighten it with
the 13mm wrench. Torque it to 15 N-m (11 ft-lb).