8
EATON
Duraforce HMR Conversion Procedures Manual E-MOPI-TM005-E July 2012
Blocking the Case Flushing Feature
Procedure to Disable the Purge Valve
Remove the purge valve.
Important
This procedure applies to
HMR Motors with Standard,
Optimized or Dampened
Shuttle Valve Assemblies.
1
Replace the existing purge valve with the blocked
purge valve
2
Install the blocked purge valve back into the motor and
torque it to 15 N-m (11 ft-lb)
3
Содержание DuraForce HMR Series
Страница 1: ...Eaton DuraForce HMR Conversion Procedures...