12
EATON
Duraforce HMR Conversion Procedures Manual E-MOPI-TM005-E July 2012
Exchanging Shuttle Valve Assemblies
Assembly Procedure
Apply Green Loctite 648 on the threads inside the rear
head where the shuttle body will be installed.
Assemble the first set of shuttle spool/shim/spring into
the shuttle body as shown during the training.
Insert the whole set into the shuttle cavity on the rear
head and torque it using the special Eaton tool (refer to
the torque chart at the bottom of this page)
Note
An HMV motor is used to
show the necessary steps
throughout this document.
The same process can be
used for HMR motors.
1
Install the plug and torque it (refer to the torque chart at
the bottom of this page).
5
2
3
Insert the second set of shuttle spool/shim/spring into
the shuttle body.
4
Item Description
Torque Value ft-lb (N-m)
Standard shuttle body
100
+7
(136
+9
)
Dampened shuttle body
44
+7
(60
+9
)
Optimized shuttle body
44
+7
(60
+9
)
Shuttle cavity plug
90
+7
(122
+9
)
Torque Chart