16
EATON
Duraforce HMR Conversion Procedures Manual E-MOPI-TM005-E July 2012
Remove the existing response orifices as shown
here.
4
Response orifices are located at the bottom of the
control block in the positions shown here.
3
Install the new response orifices into the control block
as shown here.
5
Position the control block on the motors rear head as
shown here.
6
Exchanging Response Orifices
on HMR Motors (continued)
Set Up and Procedure
Important
Inspect all o-ring on the bottom of the control block;
if necessary use petroleum jelly to secure them in
position.
Install the mounting bolts and torque them to
32 N-m (24 ft-lb).
6
Important
Make sure to orient the control correctly so that all
ports align with each other.