![Eaton Cutler-Hammer IQ DP-4000 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/eaton/cutler-hammer-iq-dp-4000/cutler-hammer-iq-dp-4000_installation-operation-and-maintenance-instructions_3743627015.webp)
IQ DP-4000
SECTION 4 - I NSTALLATION AND STARTUP
4.1 INTRODUCTION
This section provides the information for installing the IQ
DP-4000 into a metal cabinet door, and performing initial
startup. Before beginning installation, be sure to read
and understand both this section and Section 2,
Hardware Description.
I nstalling the IQ DP-4000 includes four steps:
1 . Mounting the IQ DP-4000
2. Mounting the power source separately from the
10
DP-4000 (if necessary)
3. Wiring the IQ DP-4000
4. Starting the unit for the first time
AWARNING
DO NOT HIGH-POT OR MEGGER THIS DEVICE
4.2 PANEL PREPARATION AND MOUNTING THE IQ
DP-4000
The IQ DP-4000 is typically mounted on a metal cabinet
door. To install the device you must:
•
Cut an opening in the door
•
Mount the unit
4.2. 1 Cutout, Clearances
Before mounting the IQ DP-4000 you must prepare the
cutout location. Figure 4.1 shows the chassis cutout
dimensions and the location of the ten mounting holes.
Before cutting the panel, be sure that the required 3-
dimensional clearances for the IQ DP-4000 chassis allow
mounting in the desired location (Figure 4.1 shows height
and width dimensions, while Figure 4.2 shows depth
dimensions.)
When you make the cutout and place the holes for the
mounting screws, you must hold relatively tight
tolerances. In particular, the horizontal dimension
between the center of the mounting holes and the
vertical edge must be 0.050 (0. 1 3 em) -0 inches.
4.2.2 Mounting
Place the IQ DP-4000 through the cutout in the panel,
making sure that the operator panel faces out. When you
attach the IQ DP-4000 to the door with the supplied
screws, start the screws from inside the panel so they go
through the metal door first. If you are mounting the unit
on a single-thickness panel, use 0.5 inch (1 .2 em) long
screws (included with the IQ DP-4000). The IQ DP-4000
has ten places to attach the unit to the door. The holes
12
TD1 7548A
are not threaded, but do not use a tap because this
removes excess plastic from the holes, which leaves
less threaded material for securing the IQ DP-4000 to
the mounting panel.
201 Dia
5.12
(10
:
: J
:;
'
C.25
2.56
�l
I
0.13
G
Figure 4. 1 Chassis Cutout Dimensions
www
. ElectricalPartManuals
. com