Eaton 93PM-L 20–200kW (208V) UPS Installation and Operation Manual 164000724—Rev 01
35
Table 11. Input/Output Ratings and Wiring Recommendations: 110–150 kW (220/220)
Basic Unit Rating
Units
Rating 50/60 Hz
kW
110
120
130
140
150
Input and Output Voltage
Volts
220/220
220/220
220/220
220/220
220/220
AC Input to UPS Rectifier (0.99
Minimum pF)
Full load current plus battery recharge
current
(3) Phases, (1) Ground
A
Amps
369
403
437
470
504
Minimum Conductor Size (Phase A, B,
and C)
Number per Phase
AWG or
kcmil
(each)
300 MCM
(2)
350 MCM
(2)
400 MCM
(2)
400 MCM
(2)
500 MCM
(2)
Minimum Conductor Size (Ground)
Number
–
AWG or
kcmil
(each)
2
(2)
2
(2)
1/0
(2)
1/0
(2)
1/0
(2)
AC Input to UPS Bypass (Four Wire,
Dual-Feed)
Full Load Current: (3) Phases– see
Note, (1) Ground
B
Amps
369
403
437
470
504
Neutral Current
Amps
500
545
591
636
682
Minimum Conductor Size (Phase A, B,
and C)
Number per Phase
AWG or
kcmil
(each)
400 MCM
(2)
500 MCM
(2)
300 MCM
(3)
300 MCM
(3)
350 MCM
(3)
Neutral Wire Size
Number
AWG or
kcmil
(each)
250 MCM
(4)
300 MCM
(4)
500 MCM
(3)
3/0
(6)
4/0
(6)
Minimum Conductor Size (Ground)
Number
–
AWG or
kcmil
(each)
1/0
(2)
1/0
(2)
2
(3)
2
(3)
2
(3)
DC Input from External Battery (Line-Up-and-Match Eaton 93PM-L IBC-SW, IBC-LW or IBC-LHW)
For Line-Up-and-Match wiring refer to
Eaton 93PM Integrated Battery Cabinet Installation Manual-Small Welded
or
Eaton 93PM
Universal Integrated Battery Cabinet Installation Manual-Large and Large High Rate
DC Input from External Battery
(Standalone Eaton 93PM-L IBC)
(1) Positive, (1) Negative, (1) Ground
C
Total
Amps
248
271
294
316
339
Minimum Conductor Size (Phase
Positive and Negative)
Number per Pole
AWG or
kcmil
(each)
300 MCM
(1)
350 MCM
(1)
400 MCM
(1)
500 MCM
(1)
3/0
(2)
Minimum Conductor Size (Ground)
Number
–
AWG or
kcmil
(each)
2
(1)
2
(1)
1/0
(1)
1/0
(1)
4
(2)
Содержание 93PM-L IAC-B
Страница 1: ...p n 164000724 Revision 01 20 200 kW 208V UPS Installation and Operation Manual Eaton 93PM L UPS ...
Страница 10: ...x Eaton 93PM L 20 200kW 208V UPS Installation and Operation Manual 164000724 Rev 01 List of Tables ...
Страница 112: ...102 Eaton 93PM L 20 200kW 208V UPS Installation and Operation Manual 164000724 Rev 01 UPS System Installation ...
Страница 148: ...138 Eaton 93PM L 20 200kW 208V UPS Installation and Operation Manual 164000724 Rev 01 Communication ...
Страница 154: ...144 Eaton 93PM L 20 200kW 208V UPS Installation and Operation Manual 164000724 Rev 01 UPS Maintenance ...
Страница 158: ...148 Eaton 93PM L 20 200kW 208V UPS Installation and Operation Manual 164000724 Rev 01 Product Specifications ...
Страница 161: ...Eaton 93PM L 20 200kW 208V UPS Installation and Operation Manual 164000724 Rev 01 151 Warranty ...
Страница 162: ...16400072401 164000724 01 ...