U Page 20
Digital controller RK 4004
Parameter value list (selection list)
5.2 Explanation of parameters
If the following sign ">" is set in front of the parameter it may be
edited with the help of a parameter value list (selection list) in
CANMON or DO 200. .
Editing with Canmon:
Select the "Value" field and open the parameter list via the enter key.
Select the required parameter value with the cursor keys, to mark the
parameter value press the space bar .
Editing with command station DO 200.:
Select the required parameter value via the "increase value"/"decrea-
se value" keys, to mark the parameter value press the acknowledge
key.
..0. edit device
..1. edit group
The device address consists of the device and group numbers. Each
device with a CAN connection (serial or parallel) possesses its own
device address that may only be assigned once in the entire CAN
network .
In order for a specific device to be addressed in the control loop the
device number must be set in parameter "..0. edit device" and the
group number in parameter "..1. edit group". The device and group
numbers are specified in the block diagram for each device with a
CAN address.
..2. reset settings
In the event of incorrect functioning or parameter entries, the E+L ba-
sic settings or default values may be reloaded. The following settings
are possible:
1 = perform customer settings. This customer setting is only possible
on compact systems set by E+L prior to delivery where all para-
meter settings were saved in a backup list. The setting values
are thus reloaded.
2 = perform basic settings. The default values specified in the para-
meter list are loaded. The default values are however only loaded
for the currently selected device.
No
parameter values are chan-
ged on the remaining devices.
..3. start service
Use this parameter to start various processes that are particularly re-
quired on commissioning the system. The following functions are pos-
sible: