53SL ES Series Mobile Radio Operating Manual April 2009
Error Messages
Section 10 - Tones & Error Messages
Bad Fl Fmt -
A profile/or user parameters have been downloaded to the radio that do not
match the file format supported by the firmware/software in the radio.This message may
appear on initial power up following a firmware upgrade. In such cases the message can be
cleared by doing a read/write of parameters using PCC version 2.6.x or later.
Bad Hrdwar -
The software was loaded on the wrong platform. The boot loader version
does not match the expected boot loader version. I.e., the frequency band from the ESN
may not match the RF deck frequency band.
Batt Low -
The battery voltage has been detected as being low.
Busy -
A call has been attempted and the system has responded that no channels are
available for assignment.
Busy Tmout -
The radio previously received a busy response from the system and it has
not received a channel grant before the busy time-out timer has expired.
Disabled -
The selected channel is disabled.
Clear Only -
The selected channel or group is strapped clear only and that a secure call
can not be made.
Corupt Prm -
The parameters checksum is correct, but an error exists in the parameters
file.
Cycle Power
- This error replaces the previous RX Back End Fail error. It occurs when
the radio has a communication failure with the RF Deck. This error only occurs with the X
and ES radio platforms.
Denied -
A group call attempt has received a DENIED response from the system.
Deny -
A unit or interconnect call attempt has received a DENIED response from the
system.
Disabled -
The feature that the user is attempting to use has been disabled on the radio
either by programming or by factory options.
DSP Failed -
The main processor and the DSP have failed to complete their startup
procedure at powerup.
EEPRM Fail -
The main processor has timed out while trying to validate or invalidate the
profile/user parameters in the EEPROM.
Encryp Bad -
The main processor and the Encryption Module have failed to complete
their startup procedure at power up.
Fixed High -
The selected channel or group is strapped to high power and thus low power
can not be selected.
Содержание 53SL ES Series
Страница 2: ......
Страница 4: ......
Страница 12: ...viii 53SL ES Series Mobile Radio Operating Manual April 2009 Table of Contents continued ...
Страница 16: ...xii 53SL ES Series Mobile Radio Operating Manual April 2009 List of Tables continued Table Page ...
Страница 22: ...xviii 53SL ES Series Mobile Radio Operating Manual April 2009 Safety Information ...
Страница 30: ...1 8 53SL ES Series Mobile Radio Operating Manual April 2009 Radio Accessories Section 1 Radio Overview ...
Страница 40: ...2 10 53SL ES Series Mobile Radio Operating Manual April 2009 Rear Panel Connectors Section 2 Controls Display ...
Страница 188: ...Index 4 53SL ES Series Mobile Radio Operating Manual April 2009 Index continued Zone Channel Select 4 7 Zones 4 16 ...
Страница 190: ......