7-20
53SL ES Series Mobile Radio Operating Manual April 2009
SmartZone and P25 Trunking Unique Features
Section 7 - SMARTNET / SmartZone / P25 Trunked Features
7.13.6 ZoneFail Site Lock
This is an optional feature that can be enabled only by factory programmed. It does not
require any special inputs from the infrastructure to operate. This feature is intended to
prevent some of the confusion resulting from a zone controller failure. When this occurs,
all sites go into the Site Trunking mode and radios will be unable to roam normally. The
result is that the various radios selected by a particular talkgroup may be operating on
different sites and are unable to talk to each other (see Section 7.13.2 for more Site
Trunking information).
With the Zone Fail Site Lock feature enabled, the radio continues to roam normally when
the system zone controller is active. However, if the zone controller fails, this is detected
and the Zone Fail Site Lock mode is entered. The only site the radio is then allowed to
operate on is its home site. If its home site is not available, “OUT-OF-RANGE” is
displayed. A zone controller failure is detected by determining that every site in the
dynamic site list is in Site Trunking. Currently, this condition must be detected for at least
1 minute for the Zone Fail Site Lock mode to be selected.
The result of this operation is that all radios with the same programmed home site are
forced to the home site to communicate which ensures that they can continue to
communicate. If the home site is not available, the Out-of-Range condition tells the user to
attempt communication on another system or by some other means.
7.13.7 P25 Wide Area Scan
This feature is intended to enhance roaming performance, especially when system level
steering through radio or talkgroup permissions is used.
With this option enabled on a talkgroup, as the talkgroup affiliates with a site, that site is
saved if the radio is changed to a new talkgroup. When the radio moves back to the Wide
Area Scan talkgroup, it will attempt to affiliate on the saved site before looking for a new
site.
7.13.8 Normal P25 and SmartZone Control Channel Hunt
The following control channel search methods are normally used to find a control channel:
Short Hunt -
The dynamic array of 7 adjacent sites (SmartZone) or 15 adjacent sites
(P25 Trunking) is searched. This list is saved on power down and loaded again at
power up. It is erased whenever parameters are downloaded to the radio.
Long Hunt -
If no valid control channel is located by the preceding short hunt method,
the radio searches the list of control channels programmed into the radio.
Содержание 53SL ES Series
Страница 2: ......
Страница 4: ......
Страница 12: ...viii 53SL ES Series Mobile Radio Operating Manual April 2009 Table of Contents continued ...
Страница 16: ...xii 53SL ES Series Mobile Radio Operating Manual April 2009 List of Tables continued Table Page ...
Страница 22: ...xviii 53SL ES Series Mobile Radio Operating Manual April 2009 Safety Information ...
Страница 30: ...1 8 53SL ES Series Mobile Radio Operating Manual April 2009 Radio Accessories Section 1 Radio Overview ...
Страница 40: ...2 10 53SL ES Series Mobile Radio Operating Manual April 2009 Rear Panel Connectors Section 2 Controls Display ...
Страница 188: ...Index 4 53SL ES Series Mobile Radio Operating Manual April 2009 Index continued Zone Channel Select 4 7 Zones 4 16 ...
Страница 190: ......