ATC770 Microprocessor-Based Pressure/Process Controller
53
SMART (TUNE) function in hundredths of a second. The display will show zero until the first Smart
trial.
Process Gain:
(AT.KP) will display the Process Gain value as estimated by the SMART (TUNE)
function in hundredths of units. The display will show 1.00 until the first Smart trial. The computed
value after the First Smart trial will be stored in non-volatile memory because it is used in automatic
computation of the Integral Pre Load Value.
Start Time of Smart Function:
(AT.T1) will display the time the SMART (TUNE) function started to
collect data for transient response analysis in hundredths of seconds. The display will show zero
until the first Smart trial.
Stop Time of Smart Function:
(AT.T2) will display the time the SMART (TUNE) function finished
collecting data for transient response analysis in hundredths of seconds. The display will show zero
until the first Smart trial.
Adaptive Step:
(AT.ADS) will display the integral step number used by the adaptive algorithm (the
range is 0 to 8). The display will show zero until the first Smart trial.
8.
I
NSTRUMENT
C
ALIBRATION
8.1
S
ETTING
THE
I
NTERNAL
D
IP
S
WITCH
NOTE: In this section the word Calibration means to set the Instrument to an internationally
recognized standard, independent of input device.
The instrument is shipped fully calibrated and need not be further calibrated.
Calibration of the ATC770 is a complicated procedure, requiring specialized equipment. Consult
the Dynisco technical assistance line at 800-221-2201 before attempting to work on this
instrument.
The instrument calibrations are accessible by an internal dip-switch (see below). This is done to
protect the calibration data area of the EEPROM.
Remember to change the switch settings back to the proper input as shown in Figure 13 for board
location and switch settings.
Remove the instrument from its case by gently pulling back the tabs on either side of the display.
This can be done with the unit powered, without fear of damage.
Содержание ATC770
Страница 19: ...ATC770 Microprocessor Based Pressure Process Controller 19 Fig 2 ATC770 Outline Drawing...
Страница 23: ......
Страница 30: ...30 Fig 6 Remote Set Point Jumper Location Board E...
Страница 84: ...NOTES...
Страница 85: ...NOTES...
Страница 86: ...NOTES...
Страница 88: ...DYNISCO INSTRUMENTS 38 FORGE PARKWAY FRANKLIN MA 02038 ATTN MARKETING DEPT Place Stamp Here...