26
5.2.3 O
PERATING
M
ODE
D
ESCRIPTION
The
FUNC
key is used to access the parameters organized in five groups. Use the
FUNC
pushbutton to access the Group 1 parameters; the last entry (showing
Group and nonE) is intended
to access the other groups of parameters, or pressing
FUNC
again returns to the normal display
mode. Each group has its own family of parameters, loosely grouped around the decreasing need to
change the parameters. Each group (except Group 9) also has the ability to load its own default
parameters and the default values of the lower number groups.
To reset a specific group (and lower numbered groups) to the default factory settings, press the
FUNC
key until
nonE and GROUP show on the display. Press the
▲
key until the appropriate group
number appears in the upper display. Press the
FUNC
key to enter the appropriate group. Press the
FUNC
key until
DEFLT shows on the lower display and OFF shows on the upper display. Press the
▼
or
▲
key until
ON # (where # is the Group number). Press the
FUNC
key to load the factory
parameters for that group (and lower numbered groups; for example selecting Group 5 resets groups
1, 2, 3, 4 and 5).
5.3
S
ETTING
THE
I
NSTRUMENT
’
S
B
ASIC
C
ONFIGURATION
The example below shows those parameters by group, which will permit an ATC770 to control a
motor. A modification of any other of the default parameters is not needed. Please note in the Value
column, the final values used in your process for future set-up use.
Fig. 4
Basic Parameter Table
Group #
Function
Mnemonic
Choices
Default
Value
Group 5
Primary Input Selection
PI.TYP
Str, 0-20, 4-20, 0-5, 0-10
Str
Group 5
Control Output Selection
CO.TYP
0-20, 4-20, 0-5 0-10, -10-10
0-10
Group 4
Shunt Calibration
SHUNT
OFF,On
On
Group 4
Shunt Value
SHNT%
40.0 TO 100.0%
80.0%
Group 4
Line Frequency
LINE.F
50, 60
50
Group 3
Input Full Scale Value
PI.FSV
10 TO 99.950
10000
Group 3
Input Low Scale Value
PI.LSV
±
25% OF FSV
0
Group 3
Input Decimal Point Position
PI.DP
None, 1,2,3,4 places
None
Group 3
Secondary Input T/C Type
Sl.TC
tc J, tc CA, tc L, tc n
tc J
Group 2
Zero Calibration
ZERO.C
OFF, On, CLEAr
OFF
Group 2
Span Calibration
SPAN.C
OFF, On, CLEAr
OFF
Group 2
Type of Automatic Tuning
AT.TYP
PID, PI
PI
Group 2
Self-Tuning
SMART
OFF, On
On
Group 1
Setpoint
SP
SP.LO to SP.HI
SP.LO
5.3.1 S
ETTING
THE
S
HUNT
C
ALIBRATION
:
For transducers and transmitters with a shunt calibration function (internal or external), the various
Содержание ATC770
Страница 19: ...ATC770 Microprocessor Based Pressure Process Controller 19 Fig 2 ATC770 Outline Drawing...
Страница 23: ......
Страница 30: ...30 Fig 6 Remote Set Point Jumper Location Board E...
Страница 84: ...NOTES...
Страница 85: ...NOTES...
Страница 86: ...NOTES...
Страница 88: ...DYNISCO INSTRUMENTS 38 FORGE PARKWAY FRANKLIN MA 02038 ATTN MARKETING DEPT Place Stamp Here...