Operation
ICA270-IN2EN1.pdf
2012-11-05
Interlock
The roller is equipped with Interlock.
The engine switches off 4 seconds after the operator
rises from the seat.
The engine stops whether the forward/reverse lever is
in the neutral or the drive position.
The engine does not stop if the parking brake is
activated.
Sit down for all operations!
Sit down for all operations!
Starting
Start of diesel motor
1
33
3
6
20
31
Fig. Control panel
1. Ignition starter switch
3. Emergency shut down
6. Forward/Back regulator
20. Vibration switch
31. Parking brake switch
33. Engine speed control
Make sure that the emergency stop (3) is pulled out.
Make sure that the parking brake switch (31) is
activated.
Set the forward/reverse lever (6) in neutral. The
engine can only be started when the lever is in neutral.
Turn the vibration switch (20) to the Off position
(position O).
At normal/high environmental temperature, set engine
speed control (33) at the position for idle running
(forward end position).
Turn switching starter(1) to position 3c. As soon as the
motor has started, let the starting switch go.
Do not run the starter motor for too long. If the
engine does not start, wait a minute or so before
trying again.
Do not run the starter motor for too long. If the
engine does not start, wait a minute or so before
trying again.
Idle the engine for a few minutes until it is warm,
longer if the ambient temperature is below +10 °C (50
°F)
At temperatures below 0°C (32°F) the diesel engine
and hydraulic system should be warmed up for at least
15 minutes.
36
Содержание CA270
Страница 2: ......
Страница 18: ...Special instructions ICA270 IN2EN1 pdf 2012 11 05 10...
Страница 60: ...Operating instructions Summary ICA270 IN2EN1 pdf 2012 11 05 52...
Страница 62: ...Preventive maintenance ICA270 IN2EN1 pdf 2012 11 05 54...
Страница 76: ...Maintenance 10h ICA270 IN2EN1 pdf 2012 11 05 68...
Страница 98: ......
Страница 99: ......