Maintenance - 1000h
ICA270-IN2EN1.pdf
2012-11-05
Apply a thin coat of fresh hydraulic fluid to the seal on
the new filter. Screw tight the filter by hand.
First tighten the filter until its seal is in contact with
the filter attachment. Then turn an additional half
revolution. Do not tighten the filter too hard as this
could damage the seal.
First tighten the filter until its seal is in contact with
the filter attachment. Then turn an additional half
revolution. Do not tighten the filter too hard as this
could damage the seal.
Start the engine and check that there is no leakage of
hydraulic fluid from the filter. Check level of fluid in the
sight glass (3) and top up as required.
Hydraulic fluid reservoir - Draining
Fig. Hydraulic reservoir, bottom
1. Drainage tap
2. Plug
1
2
Condensate in the hydraulic reservoir is drained via
the plug (2).
Drainage must be performed when the roller has been
stationary for an extended period, e.g. after being
stationary overnight.
Drain as
follows:
- Remove the plug (2).
- Place a container under the tap. - Open the tap (1).
Drain off any condensate.
- Close the drainage tap and refit the plug.
Save the condensate and hydraulic fluid and
hand it in to an environment-friendly waste
disposal station.
Save the condensate and hydraulic fluid and
hand it in to an environment-friendly waste
disposal station.
82
Содержание CA270
Страница 2: ......
Страница 18: ...Special instructions ICA270 IN2EN1 pdf 2012 11 05 10...
Страница 60: ...Operating instructions Summary ICA270 IN2EN1 pdf 2012 11 05 52...
Страница 62: ...Preventive maintenance ICA270 IN2EN1 pdf 2012 11 05 54...
Страница 76: ...Maintenance 10h ICA270 IN2EN1 pdf 2012 11 05 68...
Страница 98: ......
Страница 99: ......