RMO60TD Getting Started
Settings of the printer as well as look of the RMO60TD Test Report are given at figure above.
6.9 Duty Cycles
During tests, RMO60TD generates a high DC current that heats up the test set. For the test performed at
ambient temperature (25
o
C), maximal test duration times are unlimited for each test current. If the tests
are applied at higher ambient temperature, there is possibility that a built-in thermo switches prevents
RMO60TD from overheating.
The following test duration times can be applied at each test current: 30 sec, 60 sec, 90 sec, 120 sec,
180 sec, 240 sec, 300 sec, 360 sec, 420 sec, 480 sec, 540 sec, 600 sec, 660 sec, 720 sec, 780 sec,
840 sec, 900 sec, 1200 sec, 1800 sec, 3600 sec, unlimited.
C u r r e n t T e s t
Test current
(A)
Maximum test
duration time (min)
Cooling time for
maximum test
duration time (min)
5 mA, 10 mA,
50 mA,100 mA,
500 mA, 1 A, 2 A, 5 A,
10 A, 15 A, 20 A, 25 A,
30 A, 40 A, 50 A, 60 A
unlimited
0
Table 6-32:
Maximum test
duration times