background image

16

DUCATI

 

WARNINGS AND SAFETY CHECKS       

1) PRELIMINARY CHECKS BEFORE INSTALLATION:

- Check that the gate is professionally installed and complies with the safety 

standards in force in the area, that it is well balanced and equipped with mechanical 

safety stops that prevent the gate from leaving the tracks, causing serious danger to 

people and things.

- Check that the gate has the correct dimensions, weight and structure to install this 

product and that the motor dimensions are compatible with the structure.

- Check that the gate is perfectly squared and that there are no points of friction or 

obstacles that prevent correct and easy handling. The gate must be moved manually 

without too much force.

- Check that the track and the sliding wheels are underground in good condition and 

free of debris that could affect correct movement.

- Check that the flashing light is visible inside and outside the property to take into 

account an automatic movement of the gate by third parties.

WARNING: important safety tips
A) BEFORE INSTALLATION

Understand the operation and installation of the phases of your automation:

- Read the manual carefully to fully understand its operation and features.

- Check that the automation is suitable for the type, size and weight of your structure.

Check the good condition of your structure:

- Make sure your gate has been installed and is working correctly.

- Check the quality, solidity and stability of the structure.

- Check that the gate to be automated is well balanced, with no more than 2 wheels, 

that it slides well and that it does not have any friction points when it is opened 

manually.

Movement must be fluid. The gate must have strong mechanical stops that prevent it 

from coming out of the rails with the risk of falling on people or things (potential risk of 

serious injury or death!).

Warning: an engine cannot correct structural failures.

If the gate stops during travel, is altered or defective for other reasons, contact a 

qualified technician to restore the gate in good condition and before installing the 

automation structure to avoid any risk of damage or serious injury or death.!

- Before installation, restore the structure and the non-perfectly functioning gate in 

good condition.

Prevention of Serious Damage, Injury, or Death from Electric Shock:

- Make sure not to connect the 230V power supply before completing the correct 

installation of the motor (except in the case of a solar panel powered system).

- Do not connect the high voltage power supply before this procedure is indicated in 

the instruction manual.

- The installation and electrical connections must be carried out in compliance with 

all current regulations and in full compliance with the safety standards in force in the 

area.

B) DURING INSTALLATION:

Personal safety recommendation:

- Do not use accessories or clothing that could become entangled in the drive system 

or in the gate, neither during nor after the installation of the drive, to prevent these 

objects or components of the structure itself from being trapped. This could cause 

serious injury or even death from strangulation.

- Pay attention to each stage of the installation and pay the utmost attention to the 

safety of people. Make yourself aware and responsible to act to protect your safety 

and that of others.

- Do not modify the structure to try to adapt it to the engine. Always check safe and 

efficient operation and remember that the motor cannot compensate for the defects of 

a non-compliant structure, limits of use or built without respecting the best rules of the 

art and with the safety standards in force.

Prevention of serious damage:

- Avoid being near areas where there is a risk of pinching your fingers or toes.

- Do not activate the motorization before checking that there are no people, animals 

or objects in the maneuvering area. Observe the door throughout the maneuver and 

check that the area is clear throughout the maneuver cycle.

- Never leave the control devices within the reach of children and unauthorized 

persons.

- Any fixed control device must be installed min. 1.5 m above the ground.

Keep people and children away from areas with a risk of crushing or entrapment. It 

is advisable to provide protection (often a metal grid is used) to prevent people from 

approaching the movable gate and to prevent the ends from being trapped in the 

movable structure. 

Prevention of damage to the transmission system:

Remember that two main influencing factors are involved in the motorization of a 

sliding gate: the weight and the sliding fluidity of the gate: these 2 factors influence 

the inertia force of the gate, which is the main factor that allows you to evaluate 

the choice of most suitable engine. A bad evaluation can compromise the correct 

movement of the door. A very slippery gate will have a high inertial force. for a gate of 

this type it is advisable to choose a motor with slowdown to guarantee a flexible stop

.

The motors of the SLIDE series provide for the stop of the gate by detecting the 

magnetic limit switches (magnets) that must be placed along the frame. It is very 

important that the rack is correctly fixed to the gate, leveled and balanced with 

respect to the motor output gear, to avoid points of greater friction that can hinder the 

correct movement of the gate

.

   WARNING: 

A rack that is not perfectly balanced with the gate and the motor output 

gear would produce a friction point, detected by the system as an obstacle that will 

cause the motor to stop for the anti-crushing safety system. Thus preventing the door 

from moving.

WARNING: 

Pay particular attention to the correct positioning of the magnetic limit 

switches, checking that they are intercepted by the controller in front of the gate until 

the mechanical stop of the structural locks.

It is advisable to adjust the motor power level to the minimum power necessary for 

movement, checking the correct functioning of the obstacle detection safety system.

Содержание SLIDE 1043/24V

Страница 1: ...ronic board CTH43V 24V SLIDE 1043 24V Motor 24V electronic board CTH43V 24V SLIDE 446 SOLAR SOLAR Motor 12V electronic board CTH46 SLIDE 743 12V SOLAR SOLAR Motor 12V electronic board CTH43V 12V https...

Страница 2: ...12V KIT SOLAR SLIDE 743 with gearmotor model SLIDE MOT 700V 12V FAST KIT SLIDE 843 24V with gearmo tor model SLIDE MOT 800V 12V FAST KIT SLIDE 1043 24V with gearmotor model SLIDE MOT 1000V 12V FAST S...

Страница 3: ...ry to add the battery charger module Ref CMBAT optional accessory Warning use 2 12V batteries in series If only a 12V buffer battery is used it can be housed in the engine block but the engine will on...

Страница 4: ...ate 17 6 1 6 6 page 7 Temporary positioning of the limit switches 17 7 1 7 2 8 1 8 3 page 8 Power supply by 230V switch or solar panel 18 9a 9b page 9 Remote sending storage of the 1st maneuver 18 19...

Страница 5: ...lecteur cl J Clavier code sans fil en option Rail But e m canique de votre portail Orientation Sud Guide Wall Wall D 19 cm 34 cm 23 cm 1 1 DUCATI INSTALLATION DIAGRAM AND MOTOR DIMENSIONS orientaci n...

Страница 6: ...Left opening Red Blue Blue Red Direct fixing to the ground DUCATI DRAWING FOR QUICK INSTALLATION PLAK 8700 fixing plate optional Attention adjust the position of the motor on the plate to the maximum...

Страница 7: ...unlock s Place the rack on the gear one piece at a time Fix the rack piece by piece passing the same di stance from the gear the rack must always be at the same distance from the gear without major fr...

Страница 8: ...it switch Gate open limit switch M Magnet R Magnetic detector S1 Mechanical stop gate closed S2 Open gate mechanical stop Temporary adjustment of the limit switch magnets Mechanical limit switch Mecha...

Страница 9: ...powered by transformer BLACK cable YELLOW cable Boards in 24V ver sion powered by transformer BLACK cable RED cable Battery 12V min 7A Board CTH46 solar panel power supply Board CTH43V in 12V ver sio...

Страница 10: ...gnet R Reed sensor S1 Mechanical stop end limits in closed position S2 Mechanical stop end limits in open position to block To unlock Manually open the gate halfway Closed gate Press and release butto...

Страница 11: ...battery rechar ging system WARNING photocell jumper between terminals 7 and 8 Remove only the jumper when connecting a set of photocells WARNING emergency stop jumper between terminal block no 6 and...

Страница 12: ...CTH43 12V CMBAT 12V min 7A 12V min 7A CTH43 12V Radio receiver external Ref RX43 optional Radio receiver Red 24 V Yellow 12V Setting the starting point of deceleration SOFT STOP Move right to activat...

Страница 13: ...e starting point of deceleration SOFT STOP Move right to activate the settings return the switch to the left after completing the setting press P1 to delay the beginning of the slowdown press P2 to an...

Страница 14: ...TOP Setting the starting point of deceleration SOFT STOP Move right to activate the settings return the switch to the left after completing the setting press P1 to delay the beginning of the slowdown...

Страница 15: ...lock no 4 and 5 Remove the jumper only when connecting an emergency stop switch WARNING Be careful when connecting the optional battery charger Modul Ref CMBAT respect the polarity of the connections...

Страница 16: ...system or in the gate neither during nor after the installation of the drive to prevent these objects or components of the structure itself from being trapped This could cause serious injury or even...

Страница 17: ...the gate has stopped Activate the gate only if you can keep a visual check and you have verified that there are no people objects or animals in the maneuvering area Maintenance Perform regular mainte...

Страница 18: ...revent the gate from derailing causing a risk of serious danger to the life of people or things WARNING In the absence of a mechanical stop do not automate or manually operate the gate Call a speciali...

Страница 19: ...output pinion is constant over the entire length of the gate The rack must be fixed to the gate with self drilling stainless steel screws not inclu ded Assemble the rack parts using the male female r...

Страница 20: ...p left memorized by the manufacturer for the total maneuver cycle NOTE The motorization can be powered by one of the two versions of magnets MAGNO 001 or MAGNO 003 see drawings in section 7 The motori...

Страница 21: ...See diagram 14 for the CTH46 board and diagram 16 for the CTH43V 24 board Each button on the remote control corresponds to a broadcast channel The button to be used to control the motor must be store...

Страница 22: ...e contact is open the gate will not work at all until the contact closes WARNING Terminal blocks 7 8 are connected by an electric bridge to keep the photocell con tact closed Remove the bridge only if...

Страница 23: ...e sequence open stop close To set this operating mode turn the TIME knob fully counterclockwi se TIMED AUTOMATIC CLOSING mode 1 100 seconds Each remote control pulse corresponds to a complete maneuver...

Страница 24: ...will only take effect in the next cycle ELECTRONIC BOARD CTH43 Attention there are 3 versions of this board a CTH43N 12V version b CTH43V 12V version with SOFT STOP c CTH43V 24V version with SOFT STOP...

Страница 25: ...s to slow down long before recogni zing the limit switch magnet WARNING The exact adjustment of the slowdown is particularly important in the case of very heavy and or very sliding gates to manage the...

Страница 26: ...emorizes a button to command a complete maneuver cycle On the electronic board press the P1 key The red LED light turns on Release the P1 key Press the button on the remote control hold it down for a...

Страница 27: ...ON CHANNEL ON THE ELECTRONIC MOTOR BOARD On the electronic board press the P1 button to command a complete maneuver cycle or P2 on the CTH43 board and CTH46 board to command a partial pedestrian openi...

Страница 28: ...ction replace the cover on the key switch and screw the plug Electrical connection 1 Connect the two wires of the power cable to the screw terminals Diagram 4 2 Close the box diagram 2 3 Pull the cabl...

Страница 29: ...efine the position of the flashing light and then locate the punch positions 5 Plan for cable routing 6 Secure the flashing light with screws and plugs not included 7 Screw in the bulb supplied and th...

Страница 30: ...ent of the infrared ray is re established and the contact is closed Use of photocells as an opening control system Power the photocells and connect the NO contact normally open to the START contact of...

Страница 31: ...tenance relocation reinstallation of a repaired or replaced unit b Parts subject to wear such as fuses cells batteries carbon brushes light bulbs etc They are never included in the warranty c Transpor...

Страница 32: ...eristics or components of its products without notice Register on our website to receive numerous offers on other accessories and other products in our range Our commitments Support you in improving y...

Страница 33: ...33 Register in www ducatihome it VIDEO NOTICES PROMO INDEPENDENT PIECES SUPPORT 7 24h ADVICE...

Страница 34: ...utomazione cancelli via Cassani 43036 Fidenza PR ITALY Phone 39 0524 527967 Phone 39 0524 591085 Phone 0039 335 1022019 info ducatihome it REGISTER ON OUR SITE www ducatihome it TO BENEFIT FROM MANY O...

Отзывы: