![DT SWISS O.D.L. Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/dt-swiss/o-d-l/o-d-l_technical-manual_2535733053.webp)
O.D.L - Technical Manual
52
Small Service
V2016.10
Mounting the NCS Unit
1. Clean the inner surface of the left stanchion and
the whole outer surface using a dry cloth.
To prevent leakages, there must be no lint or
other residues inside the stanchion.
2. Grease the air piston (1), the spring unit (2) and
the air chamber cap (3) of the NCS unit.
There must be no grease on the inner surface
(
) of the air chamber cap (3).
Required grease, see table on page 46.
3. Position the upper unit so that the open end faces
slightly upwards.
4. Fill 2 ml DT Swiss Factory Lube Fluid into the left
stanchion.
Required oil, see table on page 46.
5. Position the upper unit horizontally.
6. Slide the NCS unit into the left stanchion while
pressing the valve insert.
The lubrication oil filled in in the last step
should not escape through the valve hole while
inserting the NCS unit.