12
Keypad Sounder Control
You can select from 21 different keypad tones. Use the arrow
keys (< >) to scroll to the desired keypad sound level and
press [#] to exit. This feature can be accessed on LED key-
pads by pressing and holding the [*] key.
[*][7] Command Output Functions
The user can activate programmable output functions using
the [*][7][1-4] commands. The outputs can be activated when
the system is either armed or disarmed.
Command Output Options 1-4:
Press [*][7][1-4][Access Code] (if required), to activate out-
puts programmed as PGM output option [19]-[22]. These out-
puts can be used for operating devices such as a garage
door opener, lighting or door strikes.
[*][7][2] – Command Output Option #2:
Press [*][7][2][Access Code, if required] to activate all outputs
programmed as one of PGM output options [03], [04] or [20].
Special Note:
Traditionally, [*][7][2] has been reserved for
resetting smoke detectors. Smoke detectors should now be
programmed as output [03] “Sensor Reset” or [04] “2-wire
Smoke”. If using output option [03] or [04], do not program
[20] Command Output Option #2. Please see 5.11
“PGM Out-
put Options”
for more information.
[*][8] Installer Programming
Enter [*][8] followed by the Installer’s Code to access
installer’s programming. See sections 4 and 5 for more infor-
mation.
[*][9] Arming Without Entry Delay
When the system is armed with the [*][9] command, the panel
will cancel the entry delay. Delay 1 and Delay 2 type zones will
be instant and Stay/Away zones will be bypassed as soon as
the exit delay has ended (see section 5.2
“Zone Program-
ming”
). The user must enter a valid access code after press-
ing [*][9].
[*][0] Quick Arm
If the
Quick Arm
option is enabled (section [015], option [4]),
enter [*][0] to arm the panel without an access code. (see
5.17
“Arming/Disarming Options”
) If the Quick Arm option is
disabled, users will need to enter an access code after press-
ing a function key.
NOTE:
Quick Arm cannot be used to cancel auto-arm.
[*][0] Quick Exit
The Quick Exit function, if enabled, will allow someone to
leave an armed premises through a Delay type zone without
having to disarm and re-arm the system. (see 5.17
“Arming/
Disarming Options”
)
When [*][0] is entered, the panel will provide a two minute win-
dow for the user to exit the premises. During this time, the
panel will ignore only one activation of a Delay zone. When the
Delay zone is secured, the panel will end the two minute quick
exit delay.
If a second Delay zone is tripped, or if the zone is not restored
after two minutes, the panel will begin entry delay 1.
NOTE:
If the Exit Delay is in progress, performing a quick exit
will not extend the Exit Delay.
3.5
Function Keys
There are five function keys on each keypad labelled Stay,
Away, Chime, Reset and Exit. Each of these keys is pro-
grammed by default to perform one of the functions described
below. Press and hold the appropriate key for two seconds to
activate a function.
If the Quick Arm option is disabled (section [015], option [4]),
users will need to enter an access code after pressing a func-
tion key.
“Stay” – (03) Stay Arm
The system will arm in the Stay mode (see 3.2
“Auto Bypass –
Stay Arming”
). Enable the Quick Arm feature (programming
section [015], option [4]) to have this key function without the
need to enter an access code. If Quick Arm is not enabled,
the user will have to enter an access code before the system
will Stay arm.
“Away” – (04) Away Arm
The system will arm in the Away mode (see 3.2
“Auto Bypass –
Stay Arming”
). Enable the Quick Arm feature (programming
section [015], option [4]) to have this key function without the
need to enter an access code. If Quick Arm is not enabled, the
user will have to enter an access code before the system will
Away arm.
When the panel is being Away armed, users can restart the exit
delay once, by pressing the Away button before the exit delay
expires. This will not work if the panel is being Stay armed.
“Chime” – (06) Door Chime On / Off
The Door Chime feature will turn ON or OFF. (see
“[*][4] Door
Chime On/Off”
)
“Reset” – (14) Sensor Reset or [*][7][2]
The panel will activate all PGM outputs programmed as option
[03] Sensor Reset or [20] Command Output Option #2. (See
“[*][7] Command Output Functions” .)
“Exit” – (16) Activate Quick Exit
The panel will activate the Quick Exit feature (see
“[*][0] Quick
Exit”
)
Additional Function Key Options
The programming of any function key on any keypad may be
changed to one of the options listed below. (See 2.6
“Keypad
Assignment”
for instructions on changing function key pro-
gramming.) Each option is listed according to the program-
ming code, followed by the corresponding [*] key command.
For more information regarding each function, please refer to
the appropriate part of Section 3.4, “[*] Commands”.
[00] Null
Key:
This key is not used and will perform no
function when pressed.
[01]
For Future Use
[02]
For Future Use
[03] Stay
Arm:
As described above.
[04] Away
Arm:
As described above.
[05]
[*][9] No Entry Delay Arm:
A valid access code
must also be entered.
[06]
[*][4] Door Chime On / Off:
As described above.
[07]
[*][6][----][4] System Test:
A valid master code must
also be entered.
[08]
[*][1] Bypass Mode:
A valid access code may need
to be entered.
[09] [*][2]
Trouble
Display
[10] [*][3]
Alarm
Memory
[11]
[*][5] Programming Access Codes:
A valid master
code must also be entered.
[12]
[*][6] User Functions:
A valid master code must also
be entered.
[13]
[*][7][1] Command Output Option #1:
A valid
access code may need to be entered.
[14]
[*][7][2] Reset (Command Output Option #2):
As
described above.