PC1550 Version 4.0
[29]
Number of Rings Before Answering
Page 13
Default
1 2
Enter a number from 01 to 12 to set the number of rings before the panel will answer.
[30]
Reset To Factory Default
Page 13
[31]
4th System Option Code
Page 14
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
Enable download answer
Disable answer
OFF
Zone Light 2
Enable download callback
Disable callback
OFF
Zone Light 3
Answering machine over-ride
Disable over-ride
OFF
Zone Light 4
Show bypass status/armed
1
1
1
1
1
Show bypass status/disarmed
OFF
Zone Light 5
AC = 50 Hz
AC = 60 Hz
OFF
Zone Light 6
Restore on bell time out
Restore as follower
•
•
•
•
•If zone light 4 is ON, bypass status will always be shown. If zone light 4 is OFF, bypass status is shown only when the panel is disarmed.
[32]
5th System Option Code
Page 14
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
AC excluded from trouble
AC included
OFF
Zone Light 2
No bell during auto-arm
Bell during auto-arm
ON
Zone Light 3
Home/away with delay
Home/away as interior
OFF
Zone Light 4
Quick exit enabled
Quick exit disabled
OFF
Zone Light 5
Force arm on auxiliary delay
Auxiliary delay normal
ON
Zone Light 6
60 s bypass on power-up
Zones active on power up
[33]
Answering Machine Double Call Timer
Page 14
Default
0 6 0
Valid entries are “001” to “249”
[34]
6th System Option Code
Page 14
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
Audible Exit Delay with Urgency
Standard Exit Delay
OFF
Zone Light 2
Bell Squawk during Exit Delay
No Bell Squawk during Exit Delay
OFF
Zone Light 3
Audible Exit Fault enabled
Audible Exit Fault disabled
OFF
Zone Light 4
Urgency applied to Entry Delay
Standard Entry Delay
OFF
Zone Light 5
Bell Squawk during Entry Delay
No Bell Squawk during Entry Delay
OFF
Zone Light 6
[F] Key disabled
[F] Key enabled
[35]
LINKS1000 Test Reporting Code
Page 14
Default
F F
Program this section only if the LINKS1000 Cellular Alarm Transmitter is being used with the PC1550.
[36]
Keypad Lockout Control
Page 14
Default
Enter 2 2-digit numbers in the range of 00 to 99. Program the Number of Invalid Codes as “00” to disable the lockout feature.
0 0
Number of Invalid Codes before lockout
0 0
Lockout Duration (minutes)
[90]
Installer’s Lockout Enable
Page 14
[91]
Installer’s Lockout Disable
Page 14
WARNING!
Panels returned to DSC with the Installer’s Lockout enabled and no other apparent problems will be subject to an
additional service charge!