16
Programming Work sheets
NOTE: In sections [01] to [10], do not enter data into sections that are not used.
[01]
1st Phone Number
Page 8
Enter [0] for the digit 0 in the phone number. Enter [
*
4
*
] (HEX D) for
additional dial tone detection between number digits, as in local PBX systems.
Enter [#] to end the phone number entry
[02]
1st Account Code
Page 8
Enter [
*
1
*
] (HEX A) for the digit “0” in the account code. For a 3-digit code, enter [0] for the 4th digit.
[03]
2nd Phone Number
Page 9
[04]
2nd Account Code
Page 9
[05]
Zone Alarm Reporting Codes
Page 9
For single digit reporting codes, enter [0] as the second digit. Enter [
*
1
*
] (HEX A) to transmit a “zero”.
Zone 1 Alarm
Zone 4 Alarm
Zone 2 Alarm
Zone 5 Alarm
Zone 3 Alarm
Zone 6 Alarm
[06]
Zone Restoral Reporting Codes
Page 9
For single digit reporting codes, enter [0] as the second digit. Enter [
*
1
*
] (HEX A) to transmit a “zero”.
Zone 1 Restoral
Zone 4 Restoral
Zone 2 Restoral
Zone 5 Restoral
Zone 3 Restoral
Zone 6 Restoral
[07]
Closing (Arming) Reporting Codes / Partial Closing Reporting Code
Page 9
Access Code 1
Access Code 4
Access Code 2
Access Code 5
Access Code 3
Access Code 6
Partial Closing Code
[08]
Opening (Disarming) Reporting Codes / After Alarm Reporting Code
Page 9
The “after alarm” code is sent on disarming if an alarm occured during the previous armed period.
Access Code 1
Access Code 4
Access Code 2
Access Code 5
Access Code 3
Access Code 6
After Alarm Code
[09]
Priority Alarms and Restorals
Page 9
Pressing the [F], [A] or [P] keys will immediately transmit both an alarm and restoral code. There is no delay on the restoral code
transmission.
Fire Loop Trouble
Fire Loop Trouble Restore
Keypad [P]anic Alarm
Keypad [P]anic Restore
Keypad [F]ire Alarm
Keypad [F]ire Restore
Keypad [A]uxiliary Alarm
Keypad [A]uxiliary Restore
[10]
Maintenance Alarms and Restorals
Page 10
For automatic test code reporting, time between reports (in days) must be specified in Section [17], and time of day for the
report must be entered in Section [19].
Low Battery Alarm
AC Fail Restore
AC Fail Alarm
Fuse Failure Restore
Fuse Failure Alarm
Automatic Test Code
Low Battery Restore
Содержание PC1550