[14] 3rd System Option Code

Use the same method of programming as section [12].

ZONE

LIGHT

[1]

ON = Access code required for bypass

• OFF = Access code not required for bypass

[2]

ON = Enable [

*

][4] downloading call feature

• OFF = Disable [

*

][4] call feature

1

1

1

1

1

[3]

ON = Periodic downloading

2

2

2

2

2

• OFF = Periodic test transmission

[4]

ON = [

*

][4] requires a access code

• OFF = [

*

][4] does not require access code

[5]

• ON = [P]anic key has keypad-audible feedback

OFF = [P]anic key without keypad-audible feedback

[6]

ON = Partial closings identified

3

3

3

3

3

• OFF = Partial closings not identified

• Factory default settings

1

When option [2] is enabled, the user or on-site installer can
initiate a call to the downloading computer by pressing [

*

][4].

2

The panel can be enabled to periodically call the downloading
computer. The cycle time (in days) for the call is set in section
[19]. The automatic call to the downloading computer can be
used to update the panel program and / or to upload status
information from the panel.

3

If partial closings are enabled as identified, then alarm codes for
the bypassed zones will be transmitted.

[15] Communication Variables

Once this section is entered, two 2-digit numbers are expected. Do
not press [#]  while entering data. The first 2-digit number defines
the number of attempts (alarm and restoral pairs) per zone that the
communicator will make before it shuts down for that zone (swinger
shutdown). The number of attempts is for the period as defined in
the 1st System Option Code Section, zone light 2. The number of
attempts may be programmed from ‘00’ to ‘99’, where ‘00’ means
the communicator will never shut down. The fire zone cannot be
shut down - it always transmits.
The second 2-digit number defines the delay before transmission,
for zones defined as burglary zones only. 24 hour loops or the fire
loop will not be delayed. The time may be programmed from ‘00’ to
‘99’ seconds, where ‘00’ means no delay.

[16] Zone Bypass Mask

Use the same method of programming as used in section [12]. If
the zone light is ON, the zone can be bypassed; if OFF, the zone
cannot be bypassed using [

*

][1]. The fire zone cannot be bypassed.

[17]

System Times

There are 6 system times which can be programmed in this section,
and each entry requires a 3-digit number. Do not press [#] during
data entry.

[1] Entry delay time 

(001 to 255 seconds)  This value determines

the standard Entry Delay time. The factory default entry time is
30 seconds. See Section [11] for zone definitions.

[2] Exit delay time 

(001 to 255 seconds)  This value determines the

standard Exit Delay time. The factory default exit time is 120
seconds. For zone definitions, see Section [11].

[3] Bell cut-off time 

(001 to 255 minutes)  This value determines

the time the bell / siren will sound before automatically turning
off. The factory default bell cut-off time is 4 minutes.

[4] AC fail transmission delay 

(001 to 255 minutes)  This value

determines the length of time before the communicator will
transmit an AC failure report. The factory default time is 30
minutes.

[5] “Slow” zone response time 

(001 to 255 × 10 ms)  This value

Section [11], Digit #2 Summary:

[0] = Standard delay loop
[1] = Instant loop
[2] = Interior Loop
[3] = Interior... home / away loop
[4] = 24 hour... bell loop
[5] = 24 hour... bell / buzzer loop
[6] = 24 hour... buzzer loop
[7] = Auxiliary delay loop
[8] = Fire Loop

[12]

1st System Option Code

The 1st System Option Code is set using the zone lights as shown
in the table below. Once section [12] is entered, the 6 zone lights
will indicate the status of each option. Press a number key
corresponding to the zone light number to turn the option ON and
OFF. Pressing [0] will turn all the zone lights OFF and the options will
be set as shown against “Light Off”.

ZONE

LIGHT

[1]

ON = Communicator disabled

• OFF = Communicator Enabled

[2]

ON = Transmission per 24 hour period

• OFF = Transmission per armed period

[3]

• ON = Alarm display while armed

OFF = No alarm display while armed

[4]

• ON = DTMF dialling

*

OFF = Pulse dialling

[5]

ON = N.C. loops (except fire loops)

• OFF = End-of-line resistor loops

[6]

• ON = Keypad [P]anic audible

OFF = Keypad [P]anic silent

• Factory default settings

*

DTMF dialling will default to pulse dialling after 2

unsuccessful DTMF dialling attempts.

[13]

2nd System Option Code

Use the same method of programming as section [12].

ZONE

LIGHT

[1]

• ON = Call 1st phone number only

OFF = Call 1st phone number with back-up to

2nd phone number

[2]

ON = Master Code not user changeable

• OFF = Master Code user changeable

[3]

ON = Bell squawk enabled*****

• OFF = Bell squawk disabled

[4]

ON = PC16OUT module enabled

• OFF = PC16OUT module disabled

[5]

ON = 6th code is “maid’s code”

(one-time use)

• OFF = 6th code is normal access code

[6]

ON = 1400 Hz handshake for Radionics

formats # 3, 4, B and C

• OFF = 2300 Hz handshake for Radionics

formats # 3, 4, B and C

• Factory default settings

*

With bell squawk enabled, the bell / siren will sound one

short burst on arming and two short bursts on disarming.

NOTE:

  

  

  

  

  When the panel is set for Auto-Arming, the bell / siren will

sound 1 short burst every 10 seconds for one minute before the
panel Auto-Arms unless the ‘Bell During Auto-Arm’ is disabled
(section [32], light 2).

Содержание PC1550

Страница 1: ...9 04 2nd Account Code 9 05 to 10 Reporting Codes 9 05 Zone Alarm Reporting Codes 9 06 Zone Restoral Reporting Codes 9 07 Closing Arming Reporting Codes Partial Closing Reporting Code 9 08 Opening Disa...

Страница 2: ...peration Download Upload capability Programmable auto downloading Swinger shutdown Transmission delay Six access codes Master key code All zones programmable as fire zones Programmable test transmissi...

Страница 3: ...witched AC source and close to the telephone line connection Remove the printed circuit board the mounting hardware and the keypad from the cardboard retainer inside the cabinet Before attaching the c...

Страница 4: ...fire generally rises to the ceiling spreads out across the ceiling surface and begins to bank down from the across the ceiling surface and begins to bank down from the across the ceiling surface and...

Страница 5: ...before going to bed and is useful for users who have a keypad outside areas protected by the interior zones Arming Without Entry Delay To eliminate Entry Delay arm the system using 9 access code An ex...

Страница 6: ...aster Code The installer may choose to not allow the user to program the Master Code section 13 option 2 The 6th code may be changed from a regular code into a One time Use code or Maid s Code section...

Страница 7: ...ammable section 14 option 5 for feedback 3 beeps or silent no buzzer feedback If programmed for audible the buzzer will sound once the key input is accepted keep time When the panel is powered up the...

Страница 8: ...mode For2 digitpairs bothdigitsmustbeprogrammed before pressing the key Only the data entered before pressing the key will be changed in the EEPROM Program Data Review Enter the section you wish to pr...

Страница 9: ...2 digit code 31 TRANSMISSION SENT 1234 31 3 1 FORMAT Extended reporting requires 3 digit Account Code in section 02 or 04 i e Enter 1230 for code 123 Format Code 8 9 A B C depending on receiver type i...

Страница 10: ...ny loop programmed for fire the Trouble light will come ON and the keypad sounder will beep every 10 seconds Thekeypadtroublebuzzerwillsoundandthe Trouble light will come ON regardless of whether the...

Страница 11: ...r zone definitions 2 Exit delay time 001 to 255 seconds This value determines the standard Exit Delay time The factory default exit time is 120 seconds For zone definitions see Section 11 3 Bell cut o...

Страница 12: ...the type of format which will be sent to each of the two telephone numbers programmed in section 01 and 03 For each telephone number enter one digit from the list below See the HEX data programming se...

Страница 13: ...he Exit Delay This option may be used to provide lighting in the exit area or to activate a device when the Exit Delay begins 0C LINKS1000 Interface This option configures the system for use with the...

Страница 14: ...Squawk during Entry Delay OFF No Bell Squawk during Entry Delay 6 ON F Key disabled OFF F Key enabled Factory default When Light 3 is ON Audible Exit Fault When the system is armed and a Standard Del...

Страница 15: ...__________________________________ ZONES Zone Type Protected Area 1 _____________________________ __________________________________________________________________ 2 _____________________________ ___...

Страница 16: ...Closing Arming Reporting Codes Partial Closing Reporting Code Page 9 Access Code 1 Access Code 4 Access Code 2 Access Code 5 Access Code 3 Access Code 6 Partial Closing Code 08 Opening Disarming Repo...

Страница 17: ...sistor loops ON Zone Light 6 Keypad P anic audible bell Keypad P anic silent bell 13 2nd System Option Code Page 11 Default Zone Light ON Zone Light OFF ON Zone Light 1 Call 1st phone only Backup to 2...

Страница 18: ...Light 6 17 System Times Page 11 Default Default 0 3 0 Entry Delay seconds 0 3 0 AC fail transmission delay minutes 1 2 0 Exit Delay seconds 0 5 0 Slow loop response time x 10 ms 0 0 4 Bell Cut off mi...

Страница 19: ...econds 7 08 Strobe Output latched alarm output 03 Utility Output Any Access Code 5 seconds 7 09 Failure to Communicate Output follows trouble 4 04 5 Second Reset Pulse 7 0A PGM ON during Entry Delay 0...

Страница 20: ...liary delay Auxiliary delay normal ON Zone Light 6 60 s bypass on power up Zones active on power up 33 Answering Machine Double Call Timer Page 14 Default 0 6 0 Valid entries are 001 to 249 34 6th Sys...

Страница 21: ...ay consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100 The Load Number of this unit is 2 AVIS L tiquette de...

Страница 22: ...ds of the Entry Delay to warn that the Entry Delay is about to expire Zone Light 5 Bell Squawk During Entry Delay The bell siren will squawk during the Entry Delay If Zone Light 4 is on the bell siren...

Страница 23: ......

Страница 24: ...l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Pour sa propre protec...

Отзывы: