Section 4: System Operation
e.g., Stay Arm partition 1 1234
Once the command is received and executed by the alarm system, the user receives a confirmation text message.
Note:
Do not use Away Arm if Push to Set [001][072] or Final Door Set [001][016] zones are programmed.
4.9 Visual Verification
This feature enables the central station operator to view captured images of the premises in the event of an alarm event.
Combination camera/motion detectors can be installed throughout the premises to provide visual verification coverage. The
microphone on the camera PIR can be disabled.
Visual verification sessions are triggered by the following:
l
Fire key
l
Medical key
l
Panic key
l
Alarms detected by armed PIR Cameras
To set up video verification on a partition:
l
Enroll the camera PIR; [804]
l
Set video verification options; [804]>[841]:
l
[001] Visual Verification Enable/Disable
l
[002] View Time Window
l
[003] View Other Alarms
l
Input a custom label to identify the camera PIR; [000]>[001]
l
Enable this option on the alternate communicator (section [10] option 2).
Refer to the Camera PIR installation manual for more details.
Note:
Visual Verification has not been evaluated by UL and shall be disabled for UL certified installations.
Note:
While an image is being transferred from the PIR camera to a central station receiver, the product cannot capture addi-
tional images.
- 56 -
Содержание Neo
Страница 6: ......
Страница 14: ...Section 2 Installation Figure 2 1 Wiring Routing North America only 14 ...
Страница 235: ......