Section 5: Programming
5.3.15 Virtual Inputs
When using an alternate communicator, virtual zones can be mapped to configured system zones.
[560][001]-[032]
Assign corresponding 3 digit zone number to virtual input and then the virtual input can be controlled by an alternate com-
municator. Refer to the communicator manual for more information
5.3.16 Schedule Programming
The sections described below are used for programming scheduled operating times for PGM command outputs 1-4.
[601]-[604] Programming Schedule 1-4
These sections are used to define schedules for PGM command outputs 1-4 operation. When a PGM is configured for timed
output operation, it activates at the programmed start time and will turn off after the programmed duration. For example, 5
seconds.
Each schedule contains 4 intervals, for Command Outputs 1-4. Within each interval, a start time and end time can be pro-
grammed for each day of the week. Holiday schedules 1-4 can also be selected. To enable the command output to follow a
schedule, program the command output in section [009] and then enter schedule 001 - 004 in section [011].
[101]-[102] Set Start Time/ End Time
Used to program the time of day the schedule interval begins and ends. (HH:MM). Valid entries are 0000-2359 and 9999.
The end time must be equal to or greater than the start time. 9999 is used when an interval needs to extend past 24 hours.
To do this, program the start time of the first interval then the end time with 9999. Program the start time of the second interval
as 9999 and the end time with the desired time when the output should deactivate. Select the day of the week the schedule
will end.
Note:
If two intervals in a schedule are programmed with the same start time, the schedule follows the interval with the
longest end time.
[103] Days Assignment
Used to program the day of the week that the schedule interval starts and ends. Use the scroll keys to select a day then
toggle the option on. Multiple days of the week can be enabled.
[104] Holiday Assignment
Program PGMs to follow holiday schedule group 1-4. Select (Y) to enable. If all days of the week for an interval are disabled
(N), the schedule activates on the enabled holidays.
[711]-[714] Holiday Schedules
Use this section to program holiday schedules. During holiday schedules, other scheduled events do not occur. Enter sec-
tion 711 to 714 for holiday group 1 to 4.
Each of the four available holiday groups can have up to 99 holiday schedules programmed.
[001]-[099] Holiday Dates 1-99
Program holiday dates in the following format: MMDDYY
MM valid entries are 01 to 12
DD valid entries are 01 to 31
YY valid entries are 00 to 99
5.3.17 [802] Audio Verification Module Programming
This module provides 2-way audio communication between the central station and the occupants of the premises.
Note:
For complete programming descriptions and worksheets, see the Audio Verification module installation manual.