Appendix 4: Regulatory Approvals
SIA False Alarm Reduction Installations: Quick Reference
Minimum required system consists of one Control unit model HS2128 or HS2064 or HS2032 or HS2016-4 and any one of
the compatible listed keypads: HS2LCDRF9, HS2LCDRFP9, HS2ICNRF9, HS2ICNRFP9, HS2LCD, HS2LCDP, HS2ICN,
HS2ICNP, HS2LED HS2TCHP.
The following wireless keys can also be used in SIA compatible installations: PG9929, PG9939,PG9949.
Note:
For models PG9929 and PG9939, the panic/emergency key shall be disabled for SIA compliant installations.
For a list of the default values programmed when the unit is shipped from the factory, and for any other programming inform-
ation, refer to the following table.
The following optional subassembly modules also bear the SIA CP-01-2010 classification and may be used if desired:
HSM2108 zone expander, HSM2208 PGM output module, HSM2300 auxiliary power supply, HSM2204 output module,
HSM2HOST9 2-way wireless transceiver, PG9901 indoor siren, PG9911 outdoor siren, and 3G2080(R)/ TL2803G(R)/ TL280
(R) cellular and PSDN communication module.
Caution
l
For SIA FAR installations use only modules/devices that are listed on this page.
l
Fire Alarm Verification feature (Auto Verified Fire Zone type [025]) is not supported on 2-wire smoke detectors zones,
model FSA-210B(T)(S)(ST)(LST)(R)(RT)(RD)(RST)(LRST). This feature may be enabled for 4-wire smoke detectors
only (FSA-410B(T)(S)(ST)(LST)(R)(RT)(RST)(LRST) and wireless detectors PG9916/PG9926). The fire alarm delay
is 60s.
l
Call Waiting Cancel (Section [382], Option 4) feature on a non-Call Waiting line will prevent successful com-
munication to the supervising station.
l
All smoke detectors on the system must be tested annually by conducting the Installer Walk Test. Prior to exiting walk
test mode, a sensor reset must be done on the system, [*][7][2], to reset all latching 4-wire smoke detectors. Refer to
the installation instructions supplied with the detector for details.
Notes
l
Programming at installation may be subordinate to other UL requirements for the intended application.
l
Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap).
l
Cross zoning is not recommended for line security Installations nor is it to be implemented on exit/entry zones.
l
This control panel has a communication delay of 30 seconds. It can be removed or increased up to 45 seconds by
the end user in consultation with the installer.
l
The security system shall be installed with the sounding device activated and the communicator enabled for trans-
mission using SIA or CID format.
l
ULC commercial burglary installations require DEOL resistors.
Important Notes for EN50131-1 compliant systems
- 213 -