Appendix 4: Regulatory Approvals
Programming
The notes in the programming sections of the PowerSeries Neo Reference Manual describing the system configurations for UL/ULC listed installations shall be imple-
mented.
Control of the Protected Premises
In order to have a UL certificated system, the protected area is to be under the responsibility of one ownership and management (i.e., one business under one name).
This may be a group of buildings attached or unattached with different addresses but under the responsibility of someone having mutual interest. The person of mutual
interest is not the alarm-installing company.
Note:
This does not apply to strip mall applications where each independent business must have their own separate alarm system.
e.g.,1: a commercial partitioned system that has an office and a warehouse area in a building where each area can be armed or disarmed independently.
e.g.,2: a residential system partitioned so that the garage area is armed separately from the house.
Each of the above examples is under the sole responsibility of a single owner. The bell and DACT power supply must be in a protected area including partitioned sys-
tems. The bell and DACT power supply must be located where it can be heard by the person or persons responsible for maintaining the security system during the
daily arming cycle.
Bell Location
The alarm sounding device (bell) shall be located where it can be heard by the person operating the security system during the daily arming and disarming cycle.
Protection of the Control Unit
l
The local control unit and the local power supply must be protected in one of the following ways:
l
The control unit and audible alarm device must be in a protected area which is armed 24 hours a day.
l
Each partition must arm the area protecting the control unit and the audible alarm device power supply. This may require duplicate protection armed by each
partition. Access to this protected area, without causing and alarm, will require that all partitions be disarmed.
l
In all cases described above, the protected area for the control unit must be programmed as not-bypassable.
Casual Users
The installer should caution the user(s) not to give system information (e.g., codes, bypass methods, etc.) to casual users (baby-sitters or service people). Only the
One-Time Use codes shall be given to casual users.
User Information
The installer should advise the users and note in the User’s Manual:
l
Service organization name and telephone number
l
The programmed exit time
l
The programmed entry time
l
Test system weekly
l
The installer code cannot arm or disarm the system
EU Compliance Statement
This Product is in Conformity with EMC Directive 2004/108/EC based on results using harmonized
standards in accordance with article 10(5), R&TTE Directive 1999/5/EC based on Following Annex III of the directive and
LVD directive 2006/95/EC based on results using Harmonized standards.
This product meets the requirements of Class II, Grade 2 equipment as per EN50131-1: 2006+A1:2009, EN50131-3:2009,
EN50131-6:2008 (Type A), EN50136-1-1:1997, EN50136-2-1, EN50136-2-3 (ATS2) Standards.
This device is suitable for use in systems with the following notification options.
A (use of two warning devices and internal dialer required
B (self-powered warning device and internal dialer required
C (use of DSC compatible alternate communicator in back-up or redundant mode)
D (use of DSC compatible alternate communicator with encryption enabled required.)
For EN50131 compliant installations only the intrusion portion of the alarm system has been investigated. Fire Alarm and
Auxiliary (Medical) Alarm functions were not included in the evaluation of this product under the requirements of the above
mentioned standards.
Additional features implemented for EN 50131 Grade 2:
Fire alarm and CO alarm annunciation
Auxiliary (medical) alarm annunciation
Optional feature implemented for EN 50131 Grade 2:
Removal from mounting tamper detection for non wire-free components
The model HS2128, HS2064, HS2032, HS2016 Control Panel has been certified by Telefication according to EN50131-
1:2006 +A1:2009, EN50131-3:2009, EN50131-6:2008 (Type A) and EN50136-1:1997 (ATS2) for Grade 2, Class II.
UK Compliance Statement