Section 6: Programming Worksheets
[011] PGM Config. Options
Description on page 85
PGM
Zone Follower by Zone
(000-128; Default 000)
Prox. Used
(000-095; Default 000)
Schedule
(000-004; Default 000)
161 PGM 161
162 PGM 162
163 PGM 163
164 PGM 164
6.6 System Lockout
[012] System Lockout
(3-Digit Decimal)
Description on page 85
Keypad Lockout:
(Range: 000-255; Default 000)
Note:
For
EN
installations maximum programmed lockout of 10
attempts.
Keypad Lockout Duration:
(Range: 001-255; Default 000)
Note:
For
EN
installations minimum programmed duration of 2 minutes.
Remote Lockout:
(Range: 003-255; Default 006)
Remote Lockout Duration:
(Range: 001-255; Default 060)
6.7 System Options
[013] System Options 1
Description on page 86
o
1 – NC Loop/EOL
o
2 – DEOL/SEOL
EN
R
2 – DEOL/SEOL
R
3 – Show All Troubles When Armed
o
4 – Tamper/Faults Open Zone
R
5 – Auto-Arm Schedule in [*][6]
R
6 – Audible Exit Fault
R
7 – Event Buffer Follows Swinger
o
8 – Temporal Three Fire Signaling
[014] System Options 2
Description on page 86
o
1 – Bell Squawk
o
2 – Bell Squawk on Auto-Arm
o
3 – Bell Squawk on Exit
- 145 -