Appendix 7: Specifications
Zone Configuration
l
16, 32, 64, or 128 wireless zones supported and up to 8 hardwired zones available on the controller
l
40 zone types and 14 programmable zone attributes
l
Zone configurations available: normally closed, single EOL and DEOL supervised
l
Hardwired zone expansion (fully supervised) available using the model HSM2108 (eight zone expander module)
l
Wireless zone expansion (fully supervised) available using the HSM2Host 2-way wireless integration module (oper-
ating at 915MHz (North America), 433MHz (Europe) and 868MHz (international)
Access Codes
l
Up to 97 access codes: 94 (level 2-EN), one system master code (level 3-EN), one installer code (level 3-EN), and
one maintenance code
l
Programmable attributes for each user code (see "Access Code Attributes" on page 49)
l
When using 6-digit access codes, the minimum number of variations of access codes are 10526 for
HS2128/HS2064,13888 for HS2032 and 20833 for HS2016-4
Warning Device Output
l
Integral sounder capable of 85 dB @ 3m, self-powered type Z
l
2 remote, wireless indoor/outdoor warning devices supported: models PGX901 (indoor), PGX911 (outdoor) (X=4, 8,
or 9)
l
Programmable as steady, pulsed or temporal three (as per ISO8201) and temporal four (CO alarm) output
l
Warning device sounds alarms in the following priority: fire, CO, burg
Memory
l
CMOS EEPROM memory
l
Retains programming and system status on AC or battery failure for 20 years min. (not verified by UL)
Power Supply - North America
Transformer: DSC PTD1640U, PTD1640
Primary: 120V, 60Hz Class II
Secondary: 16.5VAC, 40VA Max.
Power Supply - International
l
Input ratings: 220V-240Vac, 50/60Hz, 200mA
l
Transformer required, mounted in the same enclosure, permanently connected
l
Transformer secondary ratings: 16.5Vac, 40VA min.
Note:
For installations using the transformer mounted inside the cabinet, replace fuse only with the same type (20mm) rated
250V/315mA.
Regulated power supply:
l
1.7A regulated, supervised and integral to the control unit
l
Type A as per EN50131-6 Standard
l
700mA auxiliary supply, 12V DC
l
Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
l
Reverse battery detection/protection
l
Supervision for AC power and low battery
l
Normal and high current battery charge options
l
Supervised battery charging circuit
Current draw (panel):
l
85mA (nominal) 2A(Max)
Bell Output:
l
12V, 700mA supervised (1k Ohm) bell output (current limited at 2 amps)
l
Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l
Bell short detection (so hardware)
Aux+:
l
Voltage range = 9.6V - 13.8V DC
l
Current = 700mA (shared with Corbus R(ed))
l
Output ripple voltage: 270mVp-p max.