Section 5: Programming
3 – Firmware Update Fail
Sent after an unsuccessful remote firmware update.
[314] Maintenance Events 4
1/2 – Gas Trouble/Restore
Sent when a trouble occurs or is restored on a wireless gas detector.
3/4 – Heat Trouble/Restore
Sent when a heat trouble occurs or is restored on a wireless temperature detector.
5/6 – Freeze Trouble/Restore
Sent when a freeze trouble occurs or is restored on a wireless temperature detector.
7/8 – Probe Disconnected Trouble/Restore
Sent when a probe disconnected trouble occurs or is restored on a wireless temperature detector.
[321] Receiver Events
2/4/6/8 – Receiver 1 - 4 FTC Restore
Sent when the panel detects an FTC trouble.
[331] Module Events 1
1/2 – Module AC Trouble/Restore
This reporting code is transmitted when a module’s AC supply fails or has been restored. A programmable delay applies to
both the trouble and the restore. This reporting code is sent to the System Maintenance call direction group.
3/4 – Module Battery Trouble/Restore
These reporting codes are transmitted when a module’s battery voltage falls below 11.5VDC or is restored. These reporting
codes are sent to the System Maintenance call direction group.
5/6 – Module Battery Absent/Restore
These reporting codes are transmitted when a module’s battery is detected as absent or restored. These reporting codes are
sent to the System Maintenance call direction group.
[332] Module Events 2
1/2 – Module Low Voltage Trouble/Restore
Sent when module voltage drops below acceptable levels or is restored.
3/4 – Module Supervisory Trouble/Restore
Sent when communication with a module is lost or restored.
5/6 – Module Aux Trouble/Restore
Sent when a high current output module or power supply module experiences an auxiliary voltage supply trouble.
[335] Module Events 5
1/2 – Output 1 Fault/Restore
This reporting code is sent when the first output on the high-current output expander module goes into fault (open or short)
or is restored.
Only the first output on the high-current expander module is supervised.
[351] Alternate Communicator 1
1/2 – Alt. Comm Communications Fault/Restore
Sent when the system loses or restores communications with the alternate communicator.
3/4 – Not used
5/6 – Not used
7/8 – Alt. Comm Radio/SIM Failure/Restore
Sent when the alternate communicator experiences trouble or restore of the radio/SIM.
[352] Alternate Communicator 2
1/2 – Alt. Comm Network Fault/Restore
Sent when the alternate communicator loses or restores communication with the network.
5/6 – Alt. Comm Ethernet Trouble /Restore
Sent when the alternate communicator detects a network absent condition or DHCP failure or restore.
- 104 -