The air damper
dreizler A 3001 E - 18.12.2015 | A 2043 - 1.09 | EN - 01.07.2009
49
14.2 Air damper configuration
There are three important positions, which are defined exactly via limit switches:
14.3 Air damper - burner allocation
1.
Maximum burner capacity
'MAX'
2.
Minimum burner capacity
'MIN'
3.
Burner load at ignition
'IGNIT'
Burner type
Air damper
Servomotor
Model PROFI
Model HT
Model PROFI
Model HT
M 121 - M 201
integrated
L 90
SQN 71
SQN 70
M/MC 301- M/MC 1001
integrated
L 130
SQN 71
SQN 70
M/MC 1501- M/MC 5001.1
integrated
L 196
SQN 31
SQN 30
M/MC 5001- M/MC 10001.4 integrated
integrated
SQM 50
SQM 50