Dräger Polytron 8100
25
Warning interval
This function defines the time interval for the warning signal.
Refer to figure K on the fold-out page.
1. Select
Settings > Communication > Analog interface >
Warning interval
and confirm.
2. Select the line for editing
T1
and confirm.
3. Set the time and confirm.
The setting for Time T1 is displayed.
4. Select
Next
and confirm.
5. Select the line for editing
T2
and confirm.
6. Set the time and confirm.
The setting for Time T2 is displayed.
7. Select
Confirm
and confirm with [OK].
Warning current
This function defines the current for the warning signal.
1. Select
Settings > Communication > Analog interface >
Warning current
and confirm.
2. Select the line for editing the current and confirm.
3. Set the current and confirm.
The setting for the warning current is displayed.
4. Select
Confirm
and confirm with [OK].
Maintenance signal
This function selects the type of maintenance signal.
Refer to figure J on the fold-out page.
1. Select
Settings > Communication > Analog interface >
Maint. signal
and confirm.
2. Select
static
or
dynamic
signal type and confirm.
Maintenance current
This function defines the current for the maintenance signal.
1. Select
Settings > Communication > Analog interface >
Maint. current
and confirm.
2. Select the line for editing the current and confirm.
3. Set the current and confirm.
The setting for the maintenance current is displayed.
4. Select
Confirm
and confirm with [OK].
Beam block on or off
This function is only available for Polytron 87x0 (using the
sensor PIR 7x00).
Beambl. current
This function is only available for Polytron 87x0 (using the
sensor PIR 7x00.
Beamblock limit
This function is only available for Polytron 87x0 (using the
sensor PIR 7x00.
Analog offset
This function adjusts the analog output at 4 mA without
affecting the 20 mA set point. This function is useful in an
installation where the analog current at the instrument differs
from the current at the central controller.
1. Select
Settings > Communication > Analog interface >
Analog offset
and confirm.
2. Select the line for editing the offset (range: -0.5 to 0.5 mA,
SIL: -0.1 to 0.1) and confirm.
3. Set the current and confirm.
The setting for the analog offset is displayed.
4. Select
Confirm
and confirm with [OK].
Analog span
This function adjusts the analog output at 20 mA without
affecting the 4 mA set point.
1. Select
Settings > Communication > Analog interface >
Analog span
and confirm.
2. Select the line for editing the offset (range: -0.5 to 0.5 mA,
SIL: -0.1 to 0.1) and confirm.
3. Set the current and confirm.
The setting for the analog span is displayed.
4. Select
Confirm
and confirm with [OK].
Test functions for the analog interface
Set current
This function sets the current to any value between 0 and
22 mA. Analog offset and analog span are not used for this
function.
1. Select
Settings > Communication > Analog interface >
Set current
and confirm.
2. Once the alarms at the central controller are inhibited,
confirm the message
Inhibit all alarms
.
3. Select the line for editing the current and confirm.
4. Set the current and confirm.
The setting for the current is displayed.
5. Select
Next
and confirm.
6. Select
Set current out
or
Current off
and confirm.
7. Select
Next
and confirm.
The function is terminated.
8. Once the alarms at the central controller are enabled
again, confirm the message
Enable all alarms
.
NOTICE
The
static
signal type is a constant current. However,
the current value can be configured.
The
dynamic
signal type is a square wave signal with
the following characteristics.
NOTICE
The maintenance current can only be set if the
maintenance signal has been set to static.
i
i
i
i
NOTICE
These functions change the current of the analog
interface for test purposes (e.g. to check the
programming of the central controller). It might be
necessary to inhibit the alarms at the central controller
to avoid false alarms. After exiting these functions, the
currents, if changed, will automatically return to the
maintenance signal.
During the test, the maintenance symbol [
] is
displayed.
i
i
Содержание Polytron 8100
Страница 2: ......
Страница 3: ...1 5 4 3 2 5 1 4 3 10 7 8 9 2 6 3 4 5 2 1 3 9 5 2 1 14 13 3 4 5 6 7 8 14 2 11 12 15 A B C D E...
Страница 4: ...1 2 3 4 1 2 1 2 3 4 1 2 VDC mA VDC mA F G I H J K L t s 1 1 mA 0 7 5 3 t s T 1 4 20 mA T 2 3 SAMPLE...
Страница 172: ...172 Dr ger Polytron 8100 1 1 1 Dr ger Dr ger Dr ger 6 196 Dr ger EN IEC 60079 1 II 1 5 5 1 5 6 1 5 7 2014 34 EC 1 2 i i...
Страница 174: ...174 Dr ger Polytron 8100 3 3 1 10 1 204 Hawke A501 421 A NPT NPT 10 9 210 20 7 12 4 8 55 C 25 C 5 7 3 174...
Страница 182: ...182 Dr ger Polytron 8100 4 5 1 4 3 OK OK OK OK 5 8 2 188 _ _ _ 1 _ _ _ 2 4 5 2 4 5 3 OK OK 4 5 4 OK 5 OK 3 3 2 2...
Страница 198: ...198 Dr ger Polytron 8100 6 2 3 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 OK 6 6 1 1 196 6 1 2 196 Dr ger H2S ppm 25 i i 15 i i...
Страница 201: ...Dr ger Polytron 8100 201 6 4 B 1 2 2 2 3 3 4 5 4 Dr ger 5 6 7 2 22 8 9 6 2 196 10 SIL 5 6 185 5 10 4 193 i i i i...
Страница 223: ...Dr ger Polytron 8100 223 4 5 2 4 5 3 OK OK 4 5 4 OK 5 OK 3 3 2 2...
Страница 239: ...Dr ger Polytron 8100 239 6 4 B 1 2 2 2 mm 3 3 4 5 4 Dr ger 5 6 7 2 22 8 9 235 6 2 10 SIL 225 5 6 233 5 10 4 i i i i...
Страница 250: ...250 Polytron 8100 Additional Approvals A 3 Control Drawings...
Страница 252: ...252 Polytron 8100 Additional Approvals A 4 Declaration of conformity...
Страница 253: ......