11. Electric system
191
Wiring Diagram
DV2213138A
Specification
Performance
Abnormally Charging
1. Measuring the voltage between the terminal and the
alternator body when operating.
Note) Measuring the voltage in order to check the wire
condition needs only the terminal when the engine
is stopped.
1) During operation
0
.
5 MFD
B
+
P
Termianl
Regulator
R
L
B
+
R
=
150~250
OHM
L
Specification
RATING
Continuous rating
ROTATION DIRECTION
Clockwise
BATTERY VOLTAGE
24V
TURN ON RPM
Max. 1,050 RPM
SPEED IN USE
1,000 ~ 8,000 RPM
MAX. INLET AIR TEMP
105
°
C
POLARITY
SET.VOLT.
27.5V
TEMP.GRAD
10
±
3mV/
°
C
Performance
Voltage
(V)
Output current (A)
Speed
(RPM)
COLD
HOT
27.5V
(22)
17.5
1,800
(48)
45
5,000