UG6951 / UG6952 / UG6954 / UG6955 / UG6956 / UG6957
SAFEMASTER PRO fieldbus modules
4
/
17
0265998 09.05.2017 LA822P
This table shows the placement of the Fieldbus output bytes (Fieldbus module to Fieldbus PLC)
(1 byte)
B1 B0
SYSTEM STATUS
(always present)
B0=1: SAFEMASTER PRO online
B1=1: Diagnostics present
INPUTS
(Minimum: 1byte
Maximum: 16 bytes)
recognised state of
Fieldbus inputs
(1 byte)
Fieldbus probes
(2 bytes)
OUTPUTS OSSD
(max. 2 bytes)
Index of I/O
DIAGNOSTICS
(2 bytes)
see Table 2, 3
Diagnostic code
One input byte (Fieldbus PLC to Fieldbus module) must always be defined for the whished states of fieldbus inputs.
(1 Byte)
whished state of fieldbus inputs
(1 Byte)
This byte must always be present, also if no
fieldbus inputs are used in the electric schema.
If the SAFEMASTER PRO system includes a fieldbus module, the SAFEMASTER PRO Designer report will
include a table with the I/O index for all the inputs, fieldbus probes and safety outputs used in the electric
circuit.