54
≥
Command name:
+CGDCONT
[M]
・
Outline
This command sets an access point name (APN) for when dialing for
packet communication.
・
Format
+CGDCONT=[<cid>[,"<PDP_type>"[,"<APN>"]]]
・
Explanation of parameters
You set an access point name (APN) for when dialing for packet
communication.
See the example below for command instructions.
<cid>
※
: 1 to 10
<PDP_type>: PPP or IP
<APN>
※
: Arbitrary
※
<cid> is a number used to manage an access point name (APN) for
packet communication, which is registered in the FOMA phone.
You can register 1 to 10 in the FOMA phone. “mopera.ne.jp” is
registered to <cid>=1, and “mopera.net” is registered to <cid>=3,
each at purchase, so register 2 or 4 through 10.
<APN> indicates any character string for each access point name.
・
Operation at omission of parameters
+CGDCONT=
: Sets all the <cid> contents to the default.
+CGDCONT=<cid>
: Sets the specified <cid> to the default.
+CGDCONT=?
: Lists the specifiable values.
+CGDCONT?
: Displays the current setting.
・
Command execution example
AT+CGDCONT=2,"PPP","abc"
OK
※
The command used to register an APN name, abc (cid=2)
※
This command, which is a setting command, is not stored in the
nonvolatile memory written by [&W], and is not reset by [&F] and [Z],
either.
≥
Command name:
+CGEQMIN=[parameter]
[M]
・
Outline
This command registers the reference value to judge whether the
system permits QoS (Quality of service) reported from the network at
establishment of the packet communication.
You can specify four setting patterns described in the command
execution example below.
・
Format
+CGEQMIN=[<cid>[,,<Maximum bitrateUL>[,<Maximum bitrate DL>]]]
・
Explanation of parameters
<cid>
※
: 1
to
10
<Maximum bitrate UL>
※
: None (default) or 384
<Maximum bitrate DL>
※
: None (default) or 3648
※
<cid> is a number used to manage an access point name (APN) for
packet communication, which is registered in the FOMA phone.
You can register 1 to 10 in the FOMA phone. “mopera.ne.jp” is
registered to <cid>=1 and “mopera.net” is registered to <cid>=3,
each at purchase, so register 2 or 4 through 10.
<Maximum bitrate UL> and <Maximum bitrate DL> are used to
specify the minimum baud rates (kbps) for upload and download
between the FOMA phone and base station. “None” (default)
accepts all baud rates; however, 384 and 3648 do not accept a baud
rate other than 384 kbps and 3648 kbps. If you specify 384 and
3648, you may not establish packet communication.
・
Operation at omission of parameters
+CGEQMIN=
: Sets all the <cid> contents to the default.
+CGEQMIN=<cid>
: Sets the specified <cid> to the default.
Supplementary Explanation of AT
Commands
・
Command execution example
You can specify only the following four setting patterns:
(The setting in (1) is defined in each cid as the default.)
(1)Command that accepts all the baud rates for both upload and
download (cid=2)
AT+CGEQMIN=2
OK
(2)Command that accepts 384 kbps for upload and 3648 kbps for
download (cid=3)
AT+CGEQMIN=3,,384,3648
OK
(3)Command that accepts 384 kbps for upload and all baud rates for
download (cid=4)
AT+CGEQMIN=4,,384
OK
(4)Command that accepts all baud rates for upload and 3648 kbps for
download (cid=5)
AT+CGEQMIN=5,,,3648
OK
※
This command, which is a setting command, is not stored in the
nonvolatile memory written by [&W], and is not reset by [&F] and [Z],
either.
≥
Command name:
+CGEQREQ=[parameter]
[M]
・
Outline
This command sets QoS (Quality of service) to be requested to the
network at dialing of the packet communication.
You can specify only one setting pattern described in the command
execution example below, which is set as the default.
・
Format
+CGEQREQ=[<cid>]
・
Explanation of parameter
<cid>
※
: 1 to 10
※
<cid> is a number used to manage an access point name (APN) for
packet communication, which is registered in the FOMA phone.
You can register 1 to 10 in the FOMA phone. “mopera.ne.jp” is
registered to <cid>=1 and “mopera.net” is registered to <cid>=3,
each at purchase, so register 2 or 4 through 10.
・
Operation at omission of parameter
+CGEQREQ=
: Sets all the <cid> contents to the default.
+CGEQREQ=<cid>
: Sets the specified <cid> to the default.
・
Command execution example
You can specify only the following one pattern:
(This setting is defined in each cid as the default.)
(1)Command that requests a connection at 384 kbps for upload and
3648 kbps for download (cid=3)
AT+CGEQREQ=3
OK
※
This command, which is a setting command, is not stored in the
nonvolatile memory written by [&W], and is not reset by [&F] and [Z],
either.
≥
Command name:
+CLIP
・
Outline
The result for “AT+CLIP=1” is displayed in the following format:
+CLIP: <number> <type>
・
Command execution example
AT+CLIP=1
OK
RING
+CLIP: "09012345678",49
Содержание FOMA P706ie
Страница 26: ...24...
Страница 116: ...114...
Страница 130: ...128...
Страница 154: ...152...
Страница 180: ...178...
Страница 260: ...258...
Страница 281: ...279 Full Browser Displaying Web Pages Designed for PC Full Browser 280 Setting Full Browser Full Browser Settings 283...
Страница 288: ...286...
Страница 336: ...334...
Страница 410: ...408...
Страница 484: ...482 MEMO...
Страница 485: ...483 MEMO...
Страница 486: ...484 MEMO...
Страница 487: ...485 MEMO...
Страница 488: ...486 MEMO...
Страница 489: ...487 MEMO...
Страница 490: ...488 MEMO...
Страница 491: ...489 MEMO...
Страница 492: ...490 MEMO...
Страница 493: ...491 MEMO...
Страница 494: ...492...
Страница 495: ...493 Index Quick Manual Index 494 Quick Manual 502...
Страница 573: ...Kuten Code List FOMA P706ie...