36
6
Click “
接続先
(APN)
設定
[Set an access point
name (APN)]”.
“mopera.ne.jp” is registered in “cid1” and “mopera.net” is registered in
“cid3” by default. Click “
追加
(Add)”, then enter the correct access
point name (APN) for FOMA packet communication on the “
接続先
(APN)
の追加
[Add an access point name (APN)]” display. Click “OK”.
The “
パケット通信設定
(Packet communication setting)” display
returns. Select the access point name (APN) you specified newly. If it
is ok, click “OK”.
≥
For a provider access point name (APN) or supported connection
types, contact your provider.
7
Click “
詳細情報の設定
(Set detailed information)”.
The display for specifying “
IPアドレス
(IP address)” and “
ネーム
サーバ ー
(name server)” appears. When entering dial-up
information for the provider you have subscribed or Intranet LAN
system, specify addresses according to the entry instruction
information, then click “OK”.
8
Click “
次へ
(Next)”.
9
Specify “
ユーザー名
(User name)” and “
パス
ワ ード
(Password)”, then click “
次へ
(Next)”.
When specifying the user name and password, correctly enter the
information supplied from your Internet service provider, taking care
of uppercase and lowercase letters and so on.
10
Confirm the set information, then click “
完了
(Complete)”.
The set contents are listed on the display. Confirm that there is no
problem on the set contents, then click “
完了
(Complete)”.
≥
To change the set contents, click “
戻る
(Back)”.
≥
If “
デスクトップにダイヤルアップのショートカットを作成する
(Create a dial-up shortcut on the desktop)” is checked, a dial-up
shortcut will be created on the desktop.
11
Click “OK”.
The setting is completed.
Open the dial-up shortcut icon automatically created
on the desktop; then the connection display for
starting communications appears. After confirming that the
connection starts, you can start the Internet browser or mail browser
for communication. (See page 38)
The 64K data communication is a communication
system you are charged according to the duration of
connection. (Maximum communication speed: 64 kbps)
You can use the DOCOMO Internet access service,
“mopera U”/“mopera”.
1
Click “
かんたん設定
(Easy Setting)”.
2
Select “64K
データ通信
(64K data
communication)”, then click “
次へ
(Next)”.
Confirm that “64K
データ通信
(64K data communication)” is
checked, then click “
次へ
(Next)”.
3
Select “
『
mopera U
』への接続
(Connect to
mopera U)” or “
『
mopera
』への接続
(Connect
to mopera)”, then click “
次へ
(Next)”.
To use “mopera U”, select “
『
mopera U
』への接続
(Connect to mopera
U)”. To use “mopera”, select “
『
mopera
』への接続
(Connect to mopera)”.
When “
『
mopera U
』への接続
(Connect to mopera U)” is selected, the
confirmation display appears asking whether you have signed up for it. If
you have signed up, click “
はい
(YES)”.
≥
See page 37 for using a provider other than “mopera U” or “mopera”.
Select 64K Data Communication from
“
かんたん設定
(Easy Setting)”
Using “mopera U” or “mopera” as an access point
Содержание FOMA P706ie
Страница 26: ...24...
Страница 116: ...114...
Страница 130: ...128...
Страница 154: ...152...
Страница 180: ...178...
Страница 260: ...258...
Страница 281: ...279 Full Browser Displaying Web Pages Designed for PC Full Browser 280 Setting Full Browser Full Browser Settings 283...
Страница 288: ...286...
Страница 336: ...334...
Страница 410: ...408...
Страница 484: ...482 MEMO...
Страница 485: ...483 MEMO...
Страница 486: ...484 MEMO...
Страница 487: ...485 MEMO...